For S900 Series Inverters
All Rights Reserved. Subject to
change without notice.

Questions and Answers

  • A
    Angela RobinsonAug 10, 2025
    What to do if SANCH S900-4T2.2G Inverter detects over current at output side?
    • K
      Kyle BairdAug 10, 2025
      If the SANCH Inverter detects an overcurrent at the output side, take the following steps: 1. Verify that the motor's rated current matches the AC motor drive's rated current. 2. Ensure there are no short circuits in U/t1-V/t2-W/T3. 3. Confirm that there is no short circuit or grounding in the motor connection. 4. Make sure the screws are securely tightened to the AC motor drive. 5. Increase the acceleration time (parameters 1-09, 1-10). 6. Check that the motor is not overloaded.
  • M
    Michael ThomasAug 15, 2025
    What to do if output current exceeds allowable current of SANCH Inverter?
    • S
      sarah43Aug 15, 2025
      If the output current exceeds the allowable current of your SANCH Inverter, consider the following: 1. Check if the motor is overloaded. 2. Decrease the torque (parameter 7-02) to improve the set value. 3. Increase the output capacity of the AC motor drive.
  • A
    ayalamariaAug 22, 2025
    How to fix SANCH S900-4T2.2G over heat?
    • E
      Evelyn RussellAug 22, 2025
      If the SANCH Inverter detects overheating and exceeds the protection level: * Ensure the ambient environment is not overheating. * Check that the radiator and air fan are functioning correctly. * Verify that there is enough clearance for airflow around the AC motor drive.
  • M
    Mrs. Emily KennedyAug 28, 2025
    What to do if inner electric relay protection acts in SANCH S900-4T2.2G?
    • S
      suzanne85Aug 28, 2025
      If the inner electric relay protection in your SANCH Inverter activates, take these steps: 1. Check for motor overload. 2. Verify that the motor's rated current (parameter 07-00) is correct. 3. Check the electric relay function setting. 4. Increase the motor capacity.
  • J
    Jessica JacksonSep 2, 2025
    What to do if DC high voltage side over low inside SANCH S900-4T2.2G Inverter?
    • A
      April JohnsonSep 2, 2025
      If the DC high voltage side inside your SANCH Inverter is too low: * First, check that the power supply voltage is correct. * Second, ensure there is no sudden heavy load.

Summary

Inverter Safety Instructions

Operational Safety Guidelines

Critical safety guidelines for operating the inverter during wiring and use.

Environmental Operation Guidelines

Specifies environmental conditions to protect the inverter from damage and ensure safety.

Sanch Inverter Installation

Inverter Wiring Diagram

Illustrates the standard wiring connections for the main and control circuits of the inverter.

Inverter Operator Controls

Digital Operator Interface

Details the functions of the digital operator's display and control keys.

Description of Functional Parameters

Parameter Group 6: Protection Settings

Parameters for safeguarding the inverter and motor against faults.

Inverter Troubleshooting

Fault Diagnosis and Correction

Lists common fault displays and their corresponding corrective actions.

General Fault Resolution

General guidelines for diagnosing and resolving common inverter operational issues.

Inverter Maintenance

Scheduled Maintenance Checks

Outlines inspection items and methods for maintaining the inverter's condition.

SANCH S900-4T2.2G Specifications

General IconGeneral
Power2.2 kW
Voltage380V
Output Frequency0-400 Hz
Rated Power2.2 kW
Cooling MethodFan Cooling
Weight2.5 kg
Output Voltage0-380V
Protection FeaturesOverload, Overvoltage, Short Circuit
Efficiency>95%