Use a fl at-head screwdriver lever the fastening teeth of the damper (2) to remove it from the main unit (3).
Clean the damper (2) grill with a dry cloth to remove dust and general dirt. Carefully remount it in its housing until you hear
a “click” from the fastening of the teeth. Clean the main unit (3) impeller’s blades with a dry cloth.
4 PUTTING THE PRODUCT BACK IN SERVICE AFTER CLEANING
Remount the main unit (3) together with the damper (2) and embellisher cover (1) on the wall attachment (4i).
Attention: If you are cleaning several units at the same time, remount each main unit in the location you removed it from in
order to avoid communication problems between master units and slave units.
4a) RESPIRO 100 / RESPIRO 150
Simply reinstall the main wall unit and power up the product by turning it on with the master switch.
4b) RESPIRO 100 RD / RESPIRO 150 RD
Once you have put the main unit back in its wall housing, turn the product on with the master switch, to reset the cleaning
counter it is necessary to use the remote control (execution of the reset after fi lter cleaning is included in the remote control
instruction manual).