EasyManua.ls Logo

S&P SLIM Series User Manual

S&P SLIM Series
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SLIM
EN

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the S&P SLIM Series and is the answer not in the manual?

S&P SLIM Series Specifications

General IconGeneral
BrandS&P
ModelSLIM Series
CategoryHeating System
LanguageEnglish

Summary

SAFETY INSTRUCTIONS AND CE MARKING

INSTALLATION

FILTER REPLACEMENT

REMOVING THE FILTER THROUGH THE BOTTOM

Procedure for removing filters from the bottom of the unit.

INTEGRATION IN DX DIRECT EXPANSION SYSTEMS

ELECTRICAL CONNECTIONS

EXTERNAL TOUCH DISPLAY (ETD) CONNECTION

Wiring instructions for connecting the external touch display.

FACTORY WIRING

Factory wiring diagrams for different SLIM models and configurations.

Inputs & Outputs

Lists all terminal blocks and relay connections for inputs and outputs.

EXTERNAL COMPONENTS CONNECTION DRAWINGS (EXAMPLES)

Wiring examples for external components and modes.

CONTROL FUNCTIONS

FUNCTIONS

REMOTE CONTROL OPERATION

USER LEVEL

INSTALLER LEVEL

COMMISSIONING

Ventilation modes

Selecting and configuring ventilation modes (CAV, VAV, COP).

Constant airflow operation (CAV)

Detailed guide for CAV mode operation and settings.

Variable airflow operation (VAV)

Guide for VAV mode, including sensor input and airflow range.

Constant pressure operation (COP)

Guide for COP mode, focusing on pressure control.

TEMPERATURE CONTROL

REMOTE ON/OFF

REMOTE NORMAL SPEED

REMOTE EXTRA SPEED (not available in COP mode)

FREE COOLING BY NIGHT

TIME PROGRAMMING

CONFIGURE A TIME PROGRAM

Steps to set up time programs for fan speeds and holidays.

FIRE MODE

SMOKE MODE

WATER HEATER FROST PROTECTION

PROTECTION OF HEAT EXCHANGER

INSTALLATION AND CONTROL OF EXTERNAL BATTERIES

CONFIGURATION OF EXTERNAL MODULES OF REFRIGERATION/HEATING BATTERIES

Reconfiguring the SLIM controller for external cooling/heating modules.

INSTALLATION AND CONTROL OF AN ELECTRICAL PREHEATER

INSTALLATION OF AN ELECTRICAL PREHEATER

Step-by-step procedure for installing an electrical preheater.

CONFIGURATION OF AN ELECTRICAL PREHEATER

Reconfiguring the SLIM controller after installing an electrical preheater.

RESET THE CORRIGO CONTROLLER

INTEGRATION IN BUILDING MANAGEMENTS SYSTEMS (BMS)

CONNECTION TO BMS - MODBUS

Connecting to BMS using the Modbus protocol.

MODBUS RTU on port 2 - RS 485

Configuring Modbus RTU communication over RS485.

MODBUS IP on port TCP/IP

Configuring Modbus TCP/IP communication.

CONNECTION TO BMS - BACNET COMMUNICATION PROTOCOL

Connecting to BMS using the BACnet protocol.

BACnet MS/TP on port 1 - RS485

Configuring BACnet MS/TP communication over RS485.

BACnet IP on port TCP/IP

Configuring BACnet IP communication.

REDUCED LIST OF PARAMETERS FOR BMS INTEGRATION

Key parameters for BMS integration.

INSPECTION, MAINTENANCE AND CLEANING

OPERATION ANOMALIES

GENERAL ANOMALIES

Table of common anomalies, their causes, and solutions.

FAILURE LIST

Related product manuals