23
11. Technical specifi cations
Model SIH 21
Type SIH 21/2
Dimensions
(WxHxD)
300 x 180 x 100 mm
Weight 1.65 kg
Working pres-
sure
Approx. 0.8 to 1.45 bar
Atomiser filling
volume
Max. 8 ml
Min. 2 ml
Medication flow
rate
Approx. 0.4ml/min.
Sound pressure max. 52 dBA
(acc. to DIN EN 13544-1 section
26)
Mains
connection
230 V~; 50 Hz; 230 VA
UK: 240 V~; 50 Hz; 240 VA
Operating
conditions
Temperature: +10 °C – +40 °C
Relative humidity: 10% – 95%
Storage and
transport
conditions
Temperature: 0 °C – +60 °C
Relative humidity: 10% – 95%
Atmospheric pressure:
500 – 1060 hPa
Aerosol
Properties
Flow: 5.31 l/min
Aerosol delivery: 0.171 ml
Aerosol delivery rate: 0.082 ml/min
Particle size (MMAD): 3.16 µm
Subject to technical modifications.
Measurements were performed using a sodium fluoride
solution with a "Next Generation Impactor" (NGI).
All measurements were obtained with a sodium chlo-
ride solution using a laser diffraction method.
This diagram may not be applicable for suspensions
or highly viscous medicines. More information can be
obtained from the relevant medicine manufacturer.
Spare parts
SIH 21 year pack
Mouthpiece, adult/children's
mask, atomiser, compressed air
hose, filters
REF
601.20
Note
If the unit is used outside of the specifications, proper
function is no longer guaranteed!
We reserve the right to make technical changes to im-
prove and further develop the product.
This device and its accessories comply with European
standards EN60601-1 and EN60601-1-2, as well as
EN13544-1, and is subject to special safety meas-
ures in terms of electromagnetic tolerance. Note that
portable and mobile RF communication equipment
can affect this unit. For detailed information, contact
customer service at the address provided. The unit
conforms to the requirements of the European Direc-
tive for Medical Products 93/42/EC, the MPG (German
Medical units Act).
ELECTROMAGNETIC COMPATIBILITY
•
The device complies with current specifications
with regard to electromagnetic compatibility and is
suitable for use in all premises, including those des-
ignated for private residential purposes. The radio
frequency emissions of the device are extremely low
and in all probability do not cause any interference
with other devices in the proximity.
•
It is recommended that you do not place the device
on top of or close to other devices. Should you no-
tice any interference with other electrical devices,
move the unit or connect it to a different socket.
•
Radio equipment may affect the operation of this
device.