TS-1152 08/20 Rev B
Installation & Operation Instructions
Santa-Fe-Products.com | 800.533.7533
Serial Number
Install Date
Sold By
The Santa Fe Advance90 and Advance120
have a horizontal conguration and unique dual
airflow outlets that make them an ideal solution
for basements and crawl spaces. Installation
flexibility makes these units ideal for almost any
application. No conventional dehumidier
can perform as efciently and effectively
in basements and crawl spaces as the
Advance Series.
ADVANCE SERIES | ADVANCE 90
ADVANCE 120
Patent: thermastor.com/patents

Questions and Answers

  • S
    Stephanie RandolphAug 5, 2025
    Why does my Santa Fe Air Conditioner compressor keep cycling on and off?
    • R
      Richard DuncanAug 5, 2025
      The compressor in your Santa Fe Air Conditioner might be cycling on and off due to several reasons: * Low ambient temperature or humidity, which causes the unit to cycle through defrost mode. It is recommended to check ambient temperature and humidity levels. * A defective compressor overload. Consider replacing it. * A defective compressor. In that case, replacement is also required. * A defective defrost thermostat. Replacement is needed. * Dirty air filter(s) or restricted airflow. Clean or replace the air filter(s) to improve airflow. * A defective fan or relay. Replacement is needed.
  • R
    Robin SmithAug 14, 2025
    What to do if the fan and compressor of my Santa Fe Air Conditioner are not running?
    • E
      Emily HawkinsAug 15, 2025
      If neither the fan nor the compressor of your Santa Fe Air Conditioner are running when dehumidification is needed, consider the following: 1. Check if the dehumidifier is properly plugged in and that the outlet has power. 2. Ensure that the humidity control is not set too high; try lowering it. 3. Inspect the internal and control wiring for any loose connections. 4. If none of the above work, the compressor relay might be defective and require replacement.
  • D
    Daniel HallAug 25, 2025
    How to fix a Santa Fe Air Conditioner when the compressor is not running but the fan is?
    • E
      Elizabeth LongAug 25, 2025
      If the compressor in your Santa Fe Air Conditioner isn't running, but the fan is, and dehumidification is needed, it could be due to: * A defective compressor run capacitor, which needs to be replaced. * A loose connection in the compressor circuit. Check and secure any loose connections. * A defective compressor overload, which needs replacing. * A defective compressor. Replacement is required. * An open defrost thermostat. Check the defrost thermostat and replace it if it's open.

Summary

Safety Instructions

Intended Applications

Specifies intended residential use for crawl spaces/basements and operating temperature ranges.

Certifications and Compliance

Confirms compliance with UL and CSA standards for safety and performance.

Dehumidifier Setup and Installation

Items Included in Box

Lists all components provided with the Santa Fe Advance dehumidifier unit.

Important Precautions Before Setup

Details critical safety and operational considerations before installation and use.

Location Considerations for Installation

Guidance on choosing an optimal location, including drain access, electrical outlet, and clearance.

Installing Leveling Feet

Step-by-step instructions for correctly installing and adjusting the unit's leveling feet.

Drain Installation Guide

Condensate Drain Trap Setup

Explains the necessity and correct installation of a drain trap to prevent air backflow.

Using Optional Condensate Pump

Details the use of an optional condensate pump kit for elevated drain locations.

Dehumidifier Operation

Humidity Control Adjustment

Explains how to adjust the humidity control dial for desired relative humidity levels.

Defrost Cycle Function

Describes the automatic defrost feature that prevents internal frost damage during operation.

Fan Operation Modes

Details the 'FAN ON' and 'FAN AUTO' settings for continuous or dehumidifier-activated fan operation.

Air Filtration Maintenance

Filter Replacement Procedure

Provides step-by-step instructions for removing, replacing, and reinserting the air filter.

Optional Ducting Components

Attaching Duct Collars

Explains how to attach duct collars for return air inlet and supply air outlets.

Ducting Installation Recommendations

Supply Kit Only Installation

Illustrates and describes a setup using only a supply duct kit for air distribution.

Supply and Return Duct Kit Installation

Illustrates and describes a setup using both supply and return duct kits for optimal air circulation.

Troubleshooting Common Issues

Performance Troubleshooting Guide

Provides a step-by-step guide to diagnose and resolve performance issues with the dehumidifier.

Advanced Troubleshooting and Service

Refrigerant Charging Procedures

Details the procedure for recharging the refrigerant system after service or leaks.

Compressor and Capacitor Replacement

Explains the components of the compressor and the process for replacement.

Electrical Requirements and Wiring

Powering the Dehumidifier

Details power input, amperage, outlet type, and GFCI protection recommendations.

Product Warranty Information

Limited Warranty Terms and Conditions

Outlines the limited warranty period, exclusions, and customer responsibilities for claims.

Santa Fe ADVANCE90 Specifications

General IconGeneral
BrandSanta Fe
ModelADVANCE90
CategoryAir Conditioner
LanguageEnglish

Related product manuals