EasyManua.ls Logo

Sanyo C14EA80D - Page 18

Sanyo C14EA80D
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE
CONTROL
ADJUSTMENT
A
1.
Set
VR351
to
be
mechanical
center
before
pressing
the
main
switch.
2.
Tune
the
receiver
to
PAL
circular
pattern.
3.
Set
brightness
and
contrast
controls
to
normal.
4.
Connect
digital
V-meter
to
R351.
5.
By
using
VR351,
adjust
voitage
to
130
+
0.5
V.
TU-AFT
ADJUSTMENT
1.
Tune
the
receiver
to
the
clearest
station.
2.
By
using
L230,
adjust
AFT
to
obtain
the
best
picture.
A
AD
TMENT
NOTE:
Do
not
attempt
this
adjustment
with
weak
signal.
1.
Tune
the
receiver
to
the
clearest
station.
2.
Set
AGC
VR(VR120)
in
direction
which
causes
snow
noise
to
appear,
then
in
the
opposite
direction
until
snow
noise
just
disappears.
GREY
SCALE
ADJUSTMENT
(SCREEN
VR
ADJUSTMENT]
1.
Tune
the
receiver
to
black
and
white
pattern.
2.
Set
brightness
control
to
display
centre
and
contrast
control
to
normal.
3.
Set
SW220
to
“SERVICE”
position.
4.
Set
VR601and
VR611
to
be
mechanical
center.
5.
Turn
VR602,
VR612
and
VR622
fully
counter-clockwise.
6.
Set
screen
VR
for
one
colour
to
be
just
visible.
[BIAS
VR
ADJUSTMENT]
7.
By
using
VR602,
VR612
or
VR622,
adjust
line
to
be
white.
8.
Set
SW220
to
“NORMAL
position.
[DRIVE
VR
ADJUSTMENT]
9.
By
using
VR601
and
VR611,
adjust
white
balance.
!
L
DTH
NEIRM
(HIGH
VOLTAGE
CONFIRM]
1.
Tune
the
receiver
to
PAL
circular
pattern.
2.
Set
brightness
and
contrast
controls
to
normal.
3.
Connect
digital
V-meter
to
test
point
(+)
“TP-H”
and
(-)
“TP-G",
and
high
voltage
meter
to
CRT
anode.
4.
Confirm
high
voltage
to
be
21.0
+
1
KV
at
beam
current
0.7
+
0.05,
and
less
than
25.0
KV
at
0
beam
current.
(H-WIDTH
CONFIRM]
5.
If
H-width
is
too
wide
or
narrow,
connect
or
disconnect
AJ1.
6.
Reconfirm
high
voltage.
1.
Tune
the
receiver
to
PAL
circular
pattern.
2.
Adjust
H-center
by
using
VR401.
:
CIRCUIT
ALIGNMENT
VIF
ALIGNMENT
V-SIZE
ADJUSTMENT
1.
Tune
the
receiver
to
PAL
circular
pattern.
2.
Adjust
V-size
by
using
VR431.
AD.
NT
By
using
FOCUS
VR,
adjust
focus
controi
for
well
scanning
lines.
DC
15V
AGC
voltage
Output
probe
Input
probe
Tuning
voltage
Band
Damping
R
System
SW
Sweep
ATT
VIF
waveform
MAIN
BOARD
Detector
adjustment
10kQ
Input
probe
0.002uF
iW
Pe
a
75Q
1002
.
1kQ
|
Output
probe
Damping
R
DETECTOR
ADJUSTMENT
1C351-1
1C101-48
p
Tuner
TP
(Side
b)
TP-F
Tuner
TU
By
using
L230,
adjust
*P"
to
be
maximum
amplitude.
adjustment
&
Tuner
TR
OVERALL
WAVEFORM
10351-1
1C101-48
p
Tuner
TP
(Side
b)
TP-F
Tuner
TU
FREE
KV-1
&
KV-2
B/G
30
By
using
Tuner
converter
coil
and
L101,
make
the
marker
positions
to
P=35
+
10%
C=35
+
10%
Overall
waveform
Tuner
converter
coil

Related product manuals