MEMORY
IC
REPLACEMENT:
IMPORTANT
NOTE
When
IC790(X24C01P
or
X24C02P)
is
replaced,
it
is
necessary
to
initialise
the
IC
as
follows.
INITIALISATION
OF
MEMORY
IC
1.
When
you
press
and
hold
the
Function
button
on
the
TV
set
and
press
the
Recall
button
on
the
RC
transmitter,
the
following
picture
will
appear
on
the
screen.
ITEM
-
1
SET—
0
2.
Confirm
SET
number
of
ail
items
is
“O"
by
the
Function
button.
3.
If
it
is
not
"0",
change
to
"0"
by
the
Level
(+/-)
button.
(Changing
the
SET
number,
automatically
memorized.)
4.
Press
the
Recall
button,
to
return
the
normal
TV
mode.