EasyManua.ls Logo

Sanyo CE14SA4 - Grey Scale Adjustment (Items 14-17, 19-21)

Sanyo CE14SA4
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-13-
0
7
14
85
23
6
9
P
P
JXMYA
-/--
PP
TV/AV
A B
CH SCAN
TIMER
MENU
PIC MODE
SWAP
BASS
SURROUND
(1) Receive a monochrome circular pattern.
(2) Set the brightness and colour to normal, contrast to maximum.
(3) Enter to the service mode.
(4) Set each value of Item-14 RBIAS, 15 GBIAS, 16 BBIAS to 0, 17 RDRIV and 19 BDRIV to 64.
(5) Select Item-20 mode to be one horizontal scanning line and turn the screen volume on the FBT to obtain just visible
one coloured line.
(6) Press the 1 (Red Bias
-
), 2 (Red Bias +), 5 (Green Bias
-
), 6 (Green Bias +), 9 (Blue Bias
-
) or 0 (Blue Bias +)
button to adjust the brightness of each colour until a dim white line produced. Please see the control button alloca-
tions in this mode.
(7) Select Item-21 DRV mode to enter the white balance adjusting mode.
(8) Press the 3 (Red Drive
-
), 4 (Red Drive +), -/-- (Blue Drive
-
) or RECALL (Blue Drive +) button alternately to
produce normal black and white picture.
(9) Exit from the service mode.
(10) Check for proper grey scale tracking at all brightness levels.
NOTE: If the grey scale adjustment is made after picture tube replacement, check the high voltage.
Items 14-17, 19-21 GREY SCALE
Service Mode Adjustments
Red Bias
-
Red Bias +
Green Bias
-
Blue Bias +
Red Drive +
Blue Drive
-
Blue Drive +
Green Bias +
Blue Bias
-
Red Drive
-
Press the MENU
button to exit
from service
mode.
JP646
JP645
6
D432
KDY-4
KDY-3
KDY-1
T471A
T471
T471-H4
T471-H7
T471-H12
T471-H10
T471-H1T471-H2
L441
T471-H11
R477
D485
R488
R424
C471
L631
R48
R355
1
R486
R485
L441
L441A
L441-H3
C437
C435-H2 C435-H1
C435-H4
T471
FBT
MAIN BOARD
SCREEN VR
(Under side)