-8-
Service Adjustments with Replacing Memory IC (IC802)
Note: The CPU (IC801) and memory IC (IC802) store the service adjustments data and controls data for each
circuit.When the Memory IC(IC802) is replaced, some of the service adjustments should be readjusted to
obtain the best performance. The necessary service adjustments are carried out by using the RC handset.
Please set up the TV set with following steps [1] to [2].
[1] Initializing Procedure
1. Put a new memory IC.
2. Turn on the TV set.
3. Press and hold the TV/AV Selector button on the TV set for more than 2 seconds. The following picture appears on
the screen.
4. Press the PROGRAMME UP on the TV set while the above On-Screen Display is still on the screen. The following
picture appears on the screen.
This completes the initialization of memory IC.
Following shows the initialized contents of memory data by this procedure.
- Plug & Play : No executed
- Inhibit Data : Cancelled
- Ch Skip Data : Cancelled
- Sound Volume Data : 10/63 steps.
- Volume Lock : OFF
- Tuning Lock : OFF
- Music Mode : OFF
- AV Start : OFF
- Colour System : AUTO
1
CLR
CH
TV/AV
-
+
MENU
TV/AV Selector
PROGRAMME UP
[2] Required Service Adjustments
Readjust the following service adjustments.
Adjustments Service Mode No. & Item
RF AGC Item 01, RF AGC
Horizontal centre Item 02, H-PHA
Vertical size Item 04, V-SIZ
Vertical-S correction Item 05, V-SCO
Vertical linearity Item 06, V-LIN
Gray scale Item 14-17, 19-21
Further adjustment please refer to page 12 and 13.