EasyManua.ls Logo

Sanyo CMH3172A - CMH2472 A Heating Capacity Tables

Sanyo CMH3172A
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Outdoor Unit : CMH2472A
Indoor Unit : KMHS0972 × 3
Power Supply : 230V Single Phase 60Hz
< Heating Capacity >
TH : Total Heating Capacity (BTU/h)
1.
Rating conditions (#)
: Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B.
: Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B.
2.
3. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air
Prevention Protection during heating operation into account. For this reason, the value may vary
from the actual heating characteristics.
NOTE
RATING CAPACITY: 29,200 BTU/hAIR FLOW RATE: 847 CFM
OUTDOOR INDOOR
ENT. TEMP. °F (°C) AMBIENT TEMP. °F (°C)
W.B. 60 65 70 75 80
(15.6) (18.3) (21.1) (23.9) (26.7)
0 (-17.8) TH 16,550 16,540 16,510 16,470 16,420
3 (-16.1) TH 17,100 17,080 17,050 17,010 16,960
8 (-13.3) TH 18,390 18,370 18,340 18,300 18,250
13 (-10.6) TH 19,730 19,710 19,680 19,640 19,580
18 (-7.8) TH 21,200 21,180 21,150 21,100 21,040
23 (-5.0) TH 22,740 22,720 22,680 22,630 22,570
28 (-2.2) TH 24,330 24,310 24,270 24,220 24,150
33 (0.6) TH 25,970 25,950 25,900 25,850 25,770
38 (3.3) TH 27,580 27,560 27,510 27,450 27,100
43 (6.1) TH 29,280 29,250 # 29,200 29,130 27,660
48 (8.9) TH 30,990 30,950 30,900 30,830 28,150
53 (11.7) TH 32,690 32,650 32,600 31,800 28,540
58 (14.4) TH 34,320 34,280 34,220 32,140 28,820
63 (17.2) TH 35,970 35,930 35,860 32,330 28,990
65 (18.3) TH 36,600 36,560 36,110 32,370 29,010