Adjustment Method for Weight Sensor
When the main PCB or weight sensor is changed, please carry the following ‘Zero’ adjustment
out for the weight sensor.
Procedure Display
1. Plug in power cord Demonstration words
(note: please do not touch the “Clear” key) ‘WELCOME SHOWER
WAVE....’
2. Open the door
3. Place metal turntable
4. Close the door
5. Touch ‘More/Less’ key two times Flashing ‘0:00’
(No beep sound when key is touched)
6. Touch ‘Weigh Dish’ key two times
7. Touch ‘START’ key Flashing ‘0000’
8. After 4 sec. display shows 1230 Flashing ‘1230’
9. Open the door
10. Place the glass turntable
11. Close the door
12. Touch ‘START’
13. After 4 sec. display ‘1230’ stops the flashing ‘1230’
Note: When the display show the error mark “E-” during setting,please try again from the
beginning. In this case, please check if the wiring between weight sensor and main
PCB is correctly connected.