E. REMOVING DOOR
H. REMOVING TURNTABLE MOTOR COVER
(Refer to Figures 13 and
14 below)
(1) Remove the 2 screws securing the upper hinge.
(2) Tilt the top of the door toward you.
(3) Lift up the door to remove it.
NOTES
.
- After replacing the door, be sure to check that the
primary interlock switch, door sensing switch and the
interlock monitor switch operate normally. (See
page 1).
- After replacing the door check for microwave energy
leakage with a leakage detector.
Microwave energy leakage must be below the limit of
5mW/cmz.
F. DISASSEMBLING DOOR
( See exploded view on page 18)
(1) Insert a thin flat blade screwdriver between the
choke dielectric and the door mainframe and lift
up the choke dielectric to release the hooks one
by one.
7
(2) To remove door cover, remove the 2 screws
securing the door cover to the door
mainframe
—.
(3)Inserta thin flatbladescrewdriverbetweenthe
door cover and door mainframe and release the
hooks one by one.
(4) To detach the glass door panel, insert a thin fiat
blade screwdriver between the door panel and
door cover and release the clips one by one.
NOTES
- The choke dielectric, the glass door panel and the
door cover may be d?m~ged vd%n they are removed.
When re-installing them, replace them with new ones
if they are damaged.
- After installing the door in place, check icr
ii-I:G :i:z.:
energy leakage with a leakage detector.
Microwave energy leakage must be below the limit of
5mW/cmz.
G.
CHANGiNG POWER SUPPLY CORD
(See exploded view on page 16)
(1) Removing the earthing screw.
(2) Remove the power supply cord from the terminal
of PCB complete.
(3) Remove power cord from cavity assembly by
lifting cord bush, moving it to the left and pulling it
away from cavity rear plate.
(4) Install the new power supply cord with the
reverse procedure of above (1) to (3).
WARNING
For changing the power supply cord, never use parts
other than the following :
Part Name : Power Supply Cord Assembly
(1) Turn the unit and cut the 6 joints of the bottom
plate and the motor cover using diagonal pliers
(nipper). (See Figure 13)
(2) Seperate the motor cover and the bofiom plate.
NOTES
- Bend the cut joints inside slightly for safety and be
careful of the sharp edges.
RE-INSTALL :
(1) Rotate the motor cover through 180”.
(2) Insert the edge of the motor cover into the tab on
the bottom plate.
(3) Secure the motor cover by screwing it to the
bottom plate (See Figure 14)
Use screw 411 1565502 (not supplied with oven)
Inserl screw here to
Tabsfitinto
retaininglugs,
Figurel 4
Part No: 6171806519’ -
-14-