20
-
HEC-DR5000
(GENERAL)
Air-Bag Operation Confirmation Procedure
Turn ON the POWER switch at the rear of the massager while simultaneously pressing the
POSITION ADJUST "UP" and "DOWN" buttons on the remote controller (This operation should
be started with the POWER switch turned OFF).
When the examination mode is started up, both a backrest and a foot rest move slightly and
come to a stop.
Start-up of Examination Mode
Press either "WEAK" or "STRONG" button of the LOWER BODY STRENGTH adjustment on
the remote controller.
Check if the air-bag inflates sequentially as shown below.
* If there are any problems, check air leakage, breakage of air hoses, and the air-bag.
Air-Bag Operation Confirmation
1, Foot pinching, outside
2, Foot pinching, inside
3, Foot shiatsu, middle
4, Foot shiatsu, back and forth
5, Leg pinching, inside, outside
6, Leg shiatsu, lower
7, Leg shiatsu, upper
8, Thigh, right, left
OPEN
LOCK
ON
OFF
POWER
POSITION ADJUST "UP" and "DOWN" buttons
POWER switch "ON"
(Simultaneously press)
LOWER BODY STRENGTH adjusting button