ELECTRICAL
ADJUSTMENTS
EQUIPMENT
REQUIRED
VTVM
(2
sets)
Frequency
Counter
Dummy
Load
(47kQ)
Audio
Signal
Generator
Attenuator
Dualtrace
Synchroscope
DC
Constant-voltage
Regulator
Test
Tapes
*
3kHz
Test
Tape
(Example:
TEAC
MTT-111)
for
Tape
Speed
Adjustment
*
10kHz
Test
Tape
(Example:
TEAC
MTT-114)
for
Head
Azimuth
Adjustment
*
4QOHz
Test
Tape
for
Dolby
Calibration
Level
(Example:
TEAC
MTT-150)
for
Playback
Sensitivity
Adjustment
e
Test
Tapes
for
Recording
and
Playback
Operations
*
Chromium
Dioxide
Tape
(Example:
TDK
AC-51
2)
*
Metal
Tape
(Example:
TDK
AC-711)
e
Alignment
Tool
Uniess
especially
specified,
set
the
unit
and
measuring
instruments
as
follows:
@
Function
Switch
...............
ccc
cece
cece
cece
een
eeeeneneeees
LINE
@
Dolby
NR
Switch
...........
0.
ccc
c
cece
cece cece cece
eeeeeeeeeeee
OFF
e@
Tape
Select
Switch
.............cc
ccc
cec
cece
ec
enee
ee
ees
NORMAL
@
Beat
Cancel
SWitch
.............cc
cece
cece
ee
eeeeeeeeeseeeeeeees
2
@
Volume
Control
............cccceceeeeseaceseeeaeeees
Minimum
(0)
e
Audio
Signal
Generator
output.................
1kHz,
OdB
(1V)
NOTE:
*
The
Electrical
Adjustment
should
be
performed
in
the
order
as
described
below.
Supply
12V
DC
from
the
constant-voltage
regulator
to
the
Ext.
Power
Jack.
TAPE
SPEED
ADJUSTMENT
1.
Remove
the
Radio
Chassis
from
the
unit
and
connect
a
frequency
counter
to
the
left
or
right
channel
LINE
OUT
as
illustrated.
Then,
insert
a
3kHz
test
tape
(Example:
TEAC
MTT-111)
into
the
cassette
compartment.
Frequency
Counter
Dummy
Load
47kQ.
LINE
OUT
2.
Adjust
the
tape
speed
by
slowly
turning
the
potentiometer
inside
the
Motor
until
the
frequency
counter
reads
3,000Hz
(+30Hz).
Potentiometer
for
Tape
Speed
Adjustment
HEAD
AZIMUTH
ADJUSTMENT
1.
Connect
a
dualtrace
synchroscope
and
a
VTVM
to
both
channel
LINE
OUT
as
illustrated.
Then,
set
the
dualtrace
synchroscope
as
follows:
a!
|
©
D
|
<a
ene
CHOP
(chopped)
*
SOURGE.
2.2.25
5ccc.cciacsctcswes
INT
(internal),
CH1
or
CH2
*
SWEEP
MODE.................
suai
deacce
AUTO
(automatic)
NOTE:
Adjust
the
field
on
the
synchroscope
with
the
VOLT.
ADJ.
and
TIME
ADJ.

Related product manuals