Indoor Unit SAP-K97GHAX
Outdoor Unit SAP-C97GHAX
230 V Single Phase 50 Hz
28
RATING CAPACITY 2.55 kW
AIR FLOW RATE 460 m
3
/h
EVAPORATOR CONDENSER
ENT. TEMP.
C OUTDOOR AMBIENT TEMP. C
W.B. D.B. 20 25 30 35 40 43
TC 2.57 2.46 2.35 2.23 2.10 1.93
CM 0.67 0.73 0.78 0.83 0.91 0.99
21 SHC 1.80 1.74 1.69 1.63 1.57 1.49
15 23 SHC 2.03 1.98 1.93 1.87 1.81 1.73
25 SHC 2.27 2.22 2.16 2.11 2.05 1.93
27 SHC 2.51 2.46 2.35 2.23 2.10 1.93
29 SHC 2.57 2.46 2.35 2.23 2.10 1.93
31 SHC 2.57 2.46 2.35 2.23 2.10 1.93
TC 2.76 2.64 2.52 2.40 2.25 2.07
CM 0.69 0.75 0.80 0.86 0.94 1.01
21 SHC 1.55 1.50 1.44 1.39 1.33 1.25
17 23 SHC 1.79 1.74 1.68 1.63 1.56 1.49
25 SHC 2.03 1.97 1.92 1.86 1.80 1.72
27 SHC 2.27 2.21 2.16 2.10 2.04 1.96
29 SHC 2.50 2.45 2.39 2.34 2.25 2.07
31 SHC 2.74 2.64 2.52 2.40 2.25 2.07
TC 2.93 2.81 2.68
2.55 2.40 2.21
CM 0.71 0.77 0.82 0.88 0.96 1.04
21 SHC 1.30 1.24 1.19 1.14 1.07 1.00
19 23 SHC 1.54 1.48 1.43 1.37 1.31 1.23
25 SHC 1.77 1.72 1.66 1.61 1.55 1.47
27 SHC 2.01 1.96 1.90 1.85 1.79 1.71
29 SHC 2.25 2.19 2.14 2.09 2.02 1.95
31 SHC 2.49 2.43 2.38 2.32 2.26 2.18
TC 3.11 2.97 2.84 2.70 2.54 2.34
CM 0.73 0.79 0.85 0.91 0.99 1.07
23 SHC 1.28 1.22 1.17 1.12 1.06 0.98
21 25 SHC 1.52 1.46 1.41 1.36 1.29 1.22
27 SHC 1.75 1.70 1.65 1.59 1.53 1.46
29 SHC 1.99 1.94 1.88 1.83 1.77 1.69
31 SHC 2.23 2.17 2.12 2.07 2.01 1.93
TC 3.30 3.16 3.01 2.84 2.66 2.47
CM 0.75 0.81 0.87 0.93 1.02 1.10
23 25 SHC 1.24 1.19 1.14 1.08 1.01 0.95
27 SHC 1.48 1.43 1.38 1.32 1.25 1.19
29 SHC 1.72 1.67 1.61 1.55 1.49 1.43
31 SHC 1.96 1.91 1.85 1.79 1.73 1.66
TC : Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35
C D.B.
Indoor Unit Entering Air Temp. 27
C D.B. / 19 C W.B.