– Split system air conditioner –
This air conditioner uses the new refrigerant R410A.
DECLARATION OF CONFORMITY
This product is marked as it satisfies Directives:
Low voltage no.
2006/95/CE.
Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC
and 93/68 EEC.
This declaration will become void in case of misuse and/or non
observance though partial of manufacturer's installation and/or
operating instructions.
WARNING
Read the yellow instruction sheet attached to the outdoor
units.
OPERATING LIMITS
L
Cooling Maximum conditions
Outdoor temperature : 43°C D.B.
Room temperature : 32°C D.B. / 23°C W.B.
L
Cooling Minimum conditions
Outdoor temperature : 19°C D.B.
Room temperature : 19°C D.B. / 14°C W.B.
L
Heating Maximum conditions
Outdoor temperature : 24°C D.B. / 18°C W.B.
Room temperature : 27°C D.B.
L
Heating Minimum conditions
Outdoor temperature : –15°C W.B.
Room temperature : 16°C D.B.
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor Units
Outdoor Units
SAP-URV96EH SAP-CRV96EH
SAP-URV126EH SAP-CRV126EH
SAP-URV186EH SAP-CRV186EH
SAP-URV246EH SAP-CRV246EH
FOR “MULTI SPLIT” INSTALLATION SEE “MULTI DC INVERTER
COMBINATIONS TABLE”
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits ø 5
19. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
Tools required for installation (not supplied)
*
Packed in the outdoor unit.
ACCESSORIES SUPPLIED WITH THE UNIT
PARTS
Raw plug * 2
1
1
1
Ricevitore con
cavo (5 mt.)
Remote
control
FIGURE Q.TY PARTS PARTS
AAA Alkaline
battery
Drain
elbow *
2
2
2
1
4
4
Tapping
screw 4 x 30
Drain cap *
Tapping
screw 3,5 x 13
Cushion
rubber *
FIGURE FIGUREQ.TY Q.TY
Remote control
unit holder
F-GAS Regulation (EC) No. 842/2006
Do not vent R410A into atmosphere: R410A is a fluorinated
greenhouse gas, covered by Kyoto Protocol, with a Global
Warming Potential (GWP) = 1975.
Power Supply:
220 - 240 V ~ 50 Hz
INSTALLATION INSTRUCTIONS
Question and Answer IconNeed help?

Do you have a question about the Sanyo SAP-CRV186EH and is the answer not in the manual?

Sanyo SAP-CRV186EH Specifications

General IconGeneral
BrandSanyo
ModelSAP-CRV186EH
CategoryAir Conditioner
LanguageEnglish

Summary

Critical Safety Instructions

General Installation Safety Precautions

Precautions before starting installation and general warnings.

Electrical Safety Warnings

Warnings and guidelines for electrical work.

Refrigerant Connection Safety

Guidelines for connecting refrigerant tubing.

Installation Site Safety Considerations

Advice for installing in various environmental conditions.

Installation Site Selection Guidelines

Indoor Unit Location Requirements

Guidelines for choosing the best indoor installation spot.

Outdoor Unit Location Requirements

Guidelines for choosing the best outdoor installation spot.

Installation Materials and Tubing Limits

Refrigerant Tubing Specifications

Limits on length, elevation, and refrigerant quantity.

Electrical Wiring and Tube Preparation

Electrical Wiring Connection

Connecting wires to the unit.

Refrigerant Tube Preparation

Cutting and preparing copper tubes.

Refrigerant Tube Connection and Insulation

Pump Down Procedure

Pump Down Steps

Detailed procedure for pump down.

System Wiring Diagram and Specifications

System Wiring Diagram

Visual representation of electrical connections.

Wiring Specifications Table

Details on wire length, size, and fuses.

Electrical Wire Specifications

Test Run and Self-Diagnosis

Remote Control Installation

Remote Control Mounting Options

Final Electrical Connections and Checks