– Split system air conditioner –
This air conditioner uses the new refrigerant R410A.
DECLARATION OF CONFORMITY
This product is marked as it satisfies Directives:
Low voltage no.
2006/95/CE.
Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC
and 93/68 EEC.
This declaration will become void in case of misuse and/or non
observance though partial of manufacturer's installation and/or
operating instructions.
WARNING
Read the yellow instruction sheet attached to the outdoor
units.
OPERATING LIMITS
L
Cooling Maximum conditions
Outdoor temperature : 43°C D.B.
Room temperature : 32°C D.B. / 23°C W.B.
L
Cooling Minimum conditions
Outdoor temperature : 19°C D.B.
Room temperature : 19°C D.B. / 14°C W.B.
L
Heating Maximum conditions
Outdoor temperature : 24°C D.B. / 18°C W.B.
Room temperature : 27°C D.B.
L
Heating Minimum conditions
Outdoor temperature : –15°C W.B.
Room temperature : 16°C D.B.
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor Units
Outdoor Units
SAP-URV96EH SAP-CRV96EH
SAP-URV126EH SAP-CRV126EH
SAP-URV186EH SAP-CRV186EH
SAP-URV246EH SAP-CRV246EH
FOR “MULTI SPLIT” INSTALLATION SEE “MULTI DC INVERTER
COMBINATIONS TABLE”
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits ø 5
19. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
Tools required for installation (not supplied)
*
Packed in the outdoor unit.
ACCESSORIES SUPPLIED WITH THE UNIT
PARTS
Raw plug * 2
1
1
1
Ricevitore con
cavo (5 mt.)
Remote
control
FIGURE Q.TY PARTS PARTS
AAA Alkaline
battery
Drain
elbow *
2
2
2
1
4
4
Tapping
screw 4 x 30
Drain cap *
Tapping
screw 3,5 x 13
Cushion
rubber *
FIGURE FIGUREQ.TY Q.TY
Remote control
unit holder
F-GAS Regulation (EC) No. 842/2006
Do not vent R410A into atmosphere: R410A is a fluorinated
greenhouse gas, covered by Kyoto Protocol, with a Global
Warming Potential (GWP) = 1975.
Power Supply:
220 - 240 V ~ 50 Hz
INSTALLATION INSTRUCTIONS
Question and Answer IconNeed help?

Do you have a question about the Sanyo SAP-CRV246EH and is the answer not in the manual?

Sanyo SAP-CRV246EH Specifications

General IconGeneral
BrandSanyo
ModelSAP-CRV246EH
CategoryAir Conditioner
LanguageEnglish

Summary

Tools required for installation

Tools required for installation (not supplied)

Lists necessary tools for installation.

SPECIAL PRECAUTIONS

WARNING When wiring

Electrical shock hazard during wiring. Ensure proper grounding.

Installation site selection - Indoor unit

Installation site selection - Outdoor unit

Drilling and Pipe Installation

Condensate Drainage

Electrical Wiring Connection

Earth Connection

Outdoor Unit Base Installation

Connecting Refrigerant Tubes

Flare Connections

Vacuum Pump Operation

Service Valve Operation

SYSTEM WIRING DIAGRAM

Power and Connecting Wires

TEST RUN

PUMP DOWN PROCEDURE

TEST OF THE SYSTEM AND CONTROL OF THE AIR VOLUME