TECHNICAL & SERVICE MANUAL
SAP-KRV93EH + SAP-CRV93EHN
SAP-KRV123EH + SAP-CRV123EHN
DC INVERTER SPLIT SYSTEM AIR CONDITIONER
SAP-CRV93EHN
SAP-CRV123EHN
AIR CO
N
DITIONER
IMPORTANT
These air conditioners employ new
refrigerant R410A.
Pay special attention when
servicing the unit.
SAP-KRV93EH
SAP-KRV123EH
FILE NO.
REFERENCE NO. SM700598-01
Indoor Unit Outdoor Unit
Indoor Model No. Product Code No.
SAP-KRV93EH 1 852 089 81
SAP-KRV123EH 1 852 089 80
Outdoor Model No. Product Code No.
SAP-CRV93EHN 1 852 094 27
SAP-CRV123EHN 1 852 094 26
Destination: Nothen Europe
(Norway / Sweden / Finland / Denmark)
Sanyo ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com

Table of Contents

Questions and Answers:

Sanyo SAP-CRV123EHN Specifications

General IconGeneral
BrandSanyo
ModelSAP-CRV123EHN
CategoryAir Conditioner
LanguageEnglish

Summary

Special Precautions

When Wiring

Safety warnings and instructions for electrical connections and wiring procedures.

When Transporting

Guidelines for safe handling and moving of indoor and outdoor units.

When Installing

Installation considerations for different environments and conditions like walls, rooms, and wind.

When Connecting Refrigerant Tubing

Procedures for connecting refrigerant lines using the flare method for leak-free connections.

When Servicing

Safety precautions to follow during maintenance, like turning off power and keeping clear of moving parts.

Others

General safety and caution notes, including handling of refrigerant gas.

Operating Range

Specifications

Unit Specifications

Detailed technical specifications for indoor and outdoor units, including capacity, airflow, and dimensions.

Major Component Specifications

Specifications for key internal components like PCB, fan motors, and heat exchanger coils.

Other Component Specifications

Sensor resistance charts showing relationship between temperature and resistance.

Dimensional Data

Refrigerant Flow Diagram

Refrigerant Flow Diagram

Diagram illustrating the path of refrigerant through the system components.

Performance Data

Temperature Charts

Performance characteristics based on indoor/outdoor temperature variations for cooling and heating.

Air Throw Distance Charts

Charts showing airflow coverage (distance and velocity) at different flap angles.

Operating Frequency Charts

Graphs illustrating capacity and power input vs. operating frequency.

Electrical Data

Electrical Characteristics

Detailed electrical ratings and performance at specified conditions for cooling and heating.

Electric Wiring Diagrams

Diagrams showing electrical connections for indoor and outdoor units and their components.

Installation Instructions

Installation Site Selection

Guidelines for choosing appropriate locations for indoor and outdoor units, avoiding hazards.

Recommended Wire Length and Diameter

Specifications for electrical wiring based on unit model, wire length, and diameter, adhering to codes.

Remote Control Unit Installation Position

Recommended placement for the remote control unit for optimal signal reception and operation.

How to Test Run the Air Conditioner

Procedure for performing a test run to verify installation and unit operation.

Remove the Grille to Install the Indoor Unit

Step-by-step instructions for safely removing and reinstalling the indoor unit's front grille.

Maintenance

Address Setting of the Remote Control Unit

How to set unique addresses for multiple remote controls to prevent interference between units.

Disconnecting and Connecting Positive Connector for Outdoor Unit

Procedures for safely disconnecting and connecting electrical connectors on the outdoor unit.

Functions

Operation Functions

Explains various operating modes like AUTO, SENSOR DRY, Monitor, and PAM-α control for efficient operation.

Protective Functions

Details on safety features like freeze prevention, overload prevention, and discharge temperature control.

Troubleshooting

Precautions before inspection or repair

Safety guidelines and checks before starting diagnostics or repairs, including capacitor discharge.

Method of self-diagnostics

Step-by-step guide to initiate and perform the unit's self-diagnosis feature using indicator lamps.

Checking serial communications

Procedures for diagnosing communication issues between indoor and outdoor units using terminal checks.

Trouble Diagnosis of Outdoor Fan Motor

Specific troubleshooting steps and diagnostic procedures for the outdoor fan motor's operation.

Noise malfunction and electromagnetic interference

Identifying and resolving operational issues caused by external noise or electromagnetic interference.

Checking Electrical Components

Measurement of Insulation Resistance

How to measure the insulation resistance of various electrical parts and wiring for safety checks.

Checking Continuity of Fuse on PCB Ass'y

Procedure to check the continuity of a fuse on the printed circuit board assembly using a multimeter.

Refrigerant R410A: Special Precautions

Characteristics of New Refrigerant R410A

Properties, composition, and handling precautions for R410A refrigerant, noting its phase-dependent nature.

Checklist Before Servicing

Pre-servicing checks including flare tool specifications and size for R410A versus conventional tools.

Tools Specifically for R410A

List of required tools specifically for servicing R410A systems, emphasizing compatibility and proper use.

Tubing Installation Procedures

Guidelines for connecting refrigerant tubing, including oil application and precautions against dust/moisture.

In Case of Compressor Malfunction

Steps for diagnosing and replacing a malfunctioning compressor, stressing the use of R410A specific tools.

In Case Refrigerant is Leaking

Procedure for detecting, repairing, and recharging refrigerant after a leak, including welding and evacuation.

Charging Additional Refrigerant

How to add refrigerant, especially when extending tubing, with specific procedures and cautions for liquid state charging.

Retro-Fitting Existing Systems

Precautions for using R410A with older units or existing tubing, emphasizing the need for new tubing.

Features

Installation Location

Electrical Requirements

Safety Instructions

Names of Parts

Unit Display and Operation Button

Remote Control Unit

Operation with the Remote Control Unit

How to use the remote control for automatic and manual operations, including mode selection and temperature settings.

Adjusting the Fan Speed

Setting automatic or manual fan speeds for optimal airflow and comfort.

Setting the Timer

How to set the present time, OFF timer, ON timer, and daily ON/OFF repeat timers.

Care and Cleaning

Troubleshooting

Related product manuals