Outdoor Unit SAP–CRV123EHN
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Fan & Fan Motor
Type … Fan / Fan Motor Propeller / DC Motor
Q’ty … Dia. mm 1 … 400
Fan motor model … Q’ty DAJ12-55J71-C … 1
No. of poles … Rough measure rpm (Cool / Heat) 8 … 750 / 750
Nominal output W 50
Coil resistance (Ambient temp. 20°C)
Safety devices Type
Operating temp. Open °C
Close °C
Run capacitor on control PCB (A) µF
VAC
Heat Exchanger Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.4
Face area m
2
0.367
External Finish Acrylic baked-on enamel finish
Control PCB
Part No. CB-CRV123EHN (POW-CRV123GJH)
Controls Microprocessor
Control circuit fuse 250V, 20A
Compressor
Type DC Rotary (Hermetic)
Compressor model / Nominal output G4C090LU1ER / 600W
Compressor oil … Amount cc FV50S … 320
Coil resistance (Ambient temp. 20°C) U – V: 0.81
V – W: 0.81
W – U: 0.81
Safety devices
CT (Peak current cut-off control) YES
Compressor discharge temp. control YES
Operation cut-off control in abnormal ambient temp. YES
Run capacitor µF
VAC
Crankcase heater
Sanyo ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy