EasyManua.ls Logo

Sanyo SAP-CRV12AEH - Page 12

Sanyo SAP-CRV12AEH
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 20A
W819A111
Outdoor Unit SAP-CRV12AEH
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
CC
External Finish
FVC50K ... 375
Aluminum Plate Fin / Copper Tube
2
1.4
Face Area
m
2
0.357
Coil
Rows
Fin Pitch mm
Heat Exchanger Coil
Compressor Oil ... Amount
Type
Compressor Model / Nominal Output
Compressor
Coil Resistance (Ambient Temp. 20 °C)
Ohm
DC Rotary (Inverter)
1YC23AEXD / 900W
1.764
CT (Peak current cut-off control)
Compressor Discharge Temp. Control
Overload Relay
Safety Device
Model
Operation Temp.
Micro F
VAC
Run Capacitor
Crankcase Heater
Yes
Yes
-
-
-
1 ... D370
Fan
Propeller
Q'ty ... Dia. mm
Type
Micro F
VAC
2
450
FW30N ... 1
6
30
930 / 930
Ohm
AC Motor
(Ambient Temp. 20 °C)
Fan Motor
Nominal Output
Coil Resistance
Rough Measure RPM (Cool / Heat)
Run Capacitor
Type
Model ... Q'ty
No. of Poles
W
Open 120 °C
CS-7SA
Acrylic baked-on enamel finish
Main : 288.7
Aux : 188.3
95
135
Thermal protector
Open °C
°C
Operating Temp.
Type
Close
Safety Device
12

Table of Contents

Other manuals for Sanyo SAP-CRV12AEH

Related product manuals