8-4. Outdoor Fan Speed Control
To optimize performance of the air conditioner, the outdoor fan speed is switched automatically according to the
outdoor temperature.
If the outdoor air temperature falls below 28.5°C, the fan speed switches to LOW.
If the outdoor air temperature rises above 31.5°C, the fan speed switches to HIGH.
The operating temperature shown as 31.5 and 28.5 in the chart differ by models
.
H H
L
31.5
28.5
Outdoor air
temperature (°C)
Outdoor fan
speed