EasyManuals Logo

Sanyo SPW-T253GH56 Installation Instruction

Sanyo SPW-T253GH56
91 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
11
11
1
AS
22
22
2
S
33
33
3
X
44
44
4
K
55
55
5
T
66
66
6
U
77
77
7
D
88
88
8
F
99
99
9
FM
00
00
0
C
--
--
-
==
==
=
Indoor Units Type
1-Way Air Discharge
Semi-Concealed
2-Way Air Discharge
Semi-Concealed
4-Way Air Discharge
Semi-Concealed
Wall-Mounted
Ceiling-Mounted
Concealed-Duct
Concealed-Duct High
Static Pressure
Floor-Standing
Concealed Floor-Standing
Outdoor Units
Remote Controller
Weekly Timer
G
— ECO Multi System Air Conditioner —
INSTALLATION INSTRUCTION
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor Units and Outdoor Units
48
SPW-
X483GH56
SPW-
T483GH56
SPW-
U483GH56
SPW-
D483GH56
36
SPW-
X363GH56
SPW-
T363GH56
SPW-
U363GH56
SPW-
D363GH56
25
SPW-
S253GH56
SPW-
X253GH56
SPW-
T253GH56
SPW-
U253GH56
SPW-
D253GH56
SPW-
F253GH56
SPW-
FM253GH56
18
SPW-
S183GH56
SPW-
X183GH56
SPW-
K183GH56
SPW-
T183GH56
SPW-
U183GH56
SPW-
F183GH56
SPW-
FM183GH56
12
SPW-
AS123GH56
SPW-
S123GH56
SPW-
X123GH56
SPW-
K123GH56
SPW-
U123GH56
SPW-
F123GH56
SPW-
FM123GH56
9
SPW-
AS93GH56
SPW-
S93GH56
SPW-
K93GH56
SPW-
U93GH56
SPW-
F93GH56
SPW-
FM93GH56
11
11
1
AS
33
33
3
X
44
44
4
K
55
55
5
T
66
66
6
U
77
77
7
D
99
99
9
FM
00
00
0
C
--
--
-
RC
==
==
=
WT
22
22
2
S
88
88
8
F
RCS-SH80TG (Optional part )
TM-WBG (Optional part )
85464179544002 © SANYO 1996 — 1998 SANYO EIectric Co., Ltd.
Osaka, Japan
NOTE
A maximum of 13 indoor units of various types and capacities can be connected to one indoor unit.
Indoor units can be connected with a total maximum capacity of 130% of the outdoor unit capacity.
The last digit(s) of the model number indicates the required power supply to the unit.
56 : 50 Hz, (single-phase), 220 - 230 - 240 V
8 : 50 Hz, 3N~ (3-phase), 380 - 400 - 415 V
The last digit (s) of model number
SPW - C483GYH8, SPW - C703GYH8, SPW - C903GYH8
SPW - C483GY8, SPW - C703GY8, SPW - C903GY8
OPERATING LIMITS
Maximum Conditions Cooling / Heating
Outdoor temperature : 43°C DB / 15.5°C WB
Room temperature : 25°C WB / 27°C DB
Minimum Conditions
Outdoor temperature : -5°C DB / -15°C WB
Room temperature : 14°C WB / 15°C DB

Table of Contents

Other manuals for Sanyo SPW-T253GH56

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo SPW-T253GH56 and is the answer not in the manual?

Sanyo SPW-T253GH56 Specifications

General IconGeneral
BrandSanyo
ModelSPW-T253GH56
CategoryAir Conditioner
LanguageEnglish

Related product manuals