1
1-294
–15 15–5 5 25 4535
140
40
60
80
100
120
120
100
80
60
22WB
19WB
16WB
16WB
22WB
19WB
16 °C
20 °C
24 °C
16 °C
20 °C
24 °C
–15–20 –10 10 15–5 0 5
120
40
60
80
100
120
100
80
60
40
–15–20 –10 10 15–5 0 5
16 °C
20 °C
24 °C
16 °C
20 °C
24 °C
120
40
60
80
100
120
100
80
60
40
22WB
19WB
16WB
16WB
22WB
19WB
–15 15–5 5 25 4535
140
40
60
80
100
120
120
100
80
60
Input coef cient (%) Capacity coef cient (%)
Outdoor air intake temp ( °C DB)
Indoor air intake temp ( °C WB)
Indoor air intake temp ( °C WB)
Indoor air intake temp ( °C DB)
Indoor air intake temp ( °C DB)
Indoor air intake temp ( °C DB)
Indoor air intake temp ( °C DB)
Outdoor air intake temp ( °C WB)
Input coef cient (%) Capacity coef cient (%)
Outdoor air intake temp ( °C DB)
Indoor air intake temp ( °C WB)
Indoor air intake temp ( °C WB)
1-7. Capacity Correction Graph According to Temperature Condition
SPW-C366VH (For 50 Hz and 60 Hz)
SPW-C486VH (For 50 Hz and 60 Hz)
Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity)
Input coef cient (%) Capacity coef cient (%)
Input coef cient (%) Capacity coef cient (%)
Outdoor air intake temp ( °C DB)
Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity)