- 15 -
2-6. Overwriting firmware from the calibration
software
Preparation:
PC with overwriting firmware copied to the preferred folder in
the HD.
Data: 3L1xxxxx.BIN (xxxxx: version)
Overwriting method:
1. It turns on power while pushing the
ً
button and the
SET button of the CA-5 board.
2. Connect the camera’s USB terminal to the computer’s
USB connector.
3. Double-click on the DscCalDi.exe.
4. Click the Firmware.
5. Choose the fimware file to use for overwriting, and click
the Yes.
6. Update is starting. The message will appear, and choose
OK.
7. After the update is complete, disconnect the USB cable
and turn the camera’s power off.
Note:
Do not turn off the camera’s power while the firmware is be-
ing updated.