6 Parameter summary and instructions
Parameter Description
Parameters that can be modified in any state
× Parameters that cannot be modified in running state
Actual detection parameters, which cannot be modified
Manufacturer parameters, which are limited to manufacturer modification, and users are prohibited
Group F0-basic operating parameters
Code
Item
Description
Setting range
Default
Value
Amend
ment
F0.00
Power
Display current power
0.10
99.99KW
Model
setting
F0.01
Main controller
software
version
Display the current software version
number
1.0099.99
1.00
F0.02
Running
command
channel
selection
0 Panel command channel
1 Terminal command channel
2 Communication command channel
02
0
F0.03
Frequency
setting
selection
0 Panel potentiometer
1Digital setting 1, panel ▲, ▼ key
adjustment
2Digital setting 2, terminal UP /
DOWN adjustment
3AVI analog setting (0 10V)
4Combination setting
5ACI setting (0 20mA)
6Communication setting
7Pulse setting
Note: When combination setting
chosen, the combination setting is
selected in F1.15.
07
0
F0.04
Maximum
output
frequency
The maximum output frequency is the
highest frequency that the inverter is
allowed to output, and it is the
benchmark for acceleration and
deceleration settings.
MAX50.0,
F0.05】}~
999.9Hz
50.0H
z
×
F0.05
Upper limit
frequency
The operating frequency cannot exceed
this frequency
MAX{0.1
F0.06}
F0.04
50.0H
z
×
F0.06
Lower limit
frequency
The operating frequency cannot be
lower than this frequency
0.0Upper
limit
0.0Hz
×

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SANYU SY2000 Series and is the answer not in the manual?

SANYU SY2000 Series Specifications

General IconGeneral
Cooling MethodForced Air Cooling
Communication InterfaceRS485
Ambient Temperature-10°C to +40°C
Control MethodPWM
ProtectionOvervoltage
Protection FeaturesOverload
Relative Humidity<90% (no condensation)