6.3. Personal Protection Equipment
Warning!
• Always wear approved breathing and eye protection as well as
suitable protective gloves, overall and shoes when using the device
as well as during cleaning and maintenance!
6.4. Use In Explosive Areas
Thedeviceisapprovedfortheuse/storageinexplosiveareasclassied
as Ex-Zone 1 and 2.
Warning! Risk of explosion!
The following applications and operations lead to the loss of
the explosion protection and are, therefore, prohibited:
• The SATA adam 2 / SATA adam 2 mini / SATA adam 2 display must not
be brought along with or used on a spray gun in explosive areas classi-
edasEx-Zone0!
• Do not use solvents and cleaning agents based on halogenised
hydrocarbons! Chemical reaction which may occur when using these
substances may be explosive!
The electronic pressure measuring device has been submitted to a de-
sign examination and is developed, constructed and manufactured in
accordancewiththeEUdirective94/9EU.ItwasclassiedtoII2GEx
ia IIC T4 FM Global IS CL I, ZN 1, AEx ia IIC T4 IS CL I, DIV 1, GP A, B,
C&D, T4 and may be used and stored in the explosive zones 1 and 2 up
to 60°C ambient temperature. Inspection authority: KEMA 05 ATEX
1090 X.
Ex-sign
Equipment category
Gas category
Type of ignition protection
Temperature
classication
Device category Equipment category
II 2 G Ex ia IIC T4
II 2 G Ex ia IIC T4
IECEx label: IECEx KEM 09.0075