FUNCTIONAL DESCRIPTION
9
If the object is watched by guard, the round monitoring and signalling of guard
absence in specified time is possible – when the guard types his code on a partition
or lock keypad; this is registered in the memory of events. Times connected with that
are declared for each partition separately; when “0” time is programmed, the
monitoring function is switched off. It is possible to differentiate monitoring times
depending on whether the partition is armed or not. When partition round requires
violation of detectors and the guard has no right to switch detectors off, it is possible
to programme the bypass time period, which starts when the guard enters his code to
make a round. The guard may use a proximity card or DALLAS chip when carrying
out the round. Also, partition bypass may be activated by entering the code like
“Temporary partition bypass”.
If the system protects cash points by means of zones type “24 h – for cash points”,
each partition may contain one cash point only. Access to the cash point is possible
after entering the code of type “ Cash point bypass” from LCD keypad (or computer).
This bypass starts the “time for approaching” the cash point (“24 h – for cash points”
zone is still armed), and, after that time period, bypass time period is counted-down
(then “24 h – for cash points” zone is bypassed).