2 SAFETY
DANGER!
Risk of electric shock!
The magnetic holding force is switched on and off with current pulses.
Electro permanent magnetic chucks use high magnetising and demagnetis-
ing voltages. An electric shock can result in death or serious injuries.
■
Always protect the junction box and rubberised cable against damage.
■
To exclude malfunctions and hazards for the operator, it must be ensured
that the junction box is sealed, in particular during wet work and after
any repair work.
■
Electrical connections must always be installed by a qualified electri-
cian (as per VDE 1000 Part 10). The regulations of VDE 0100 must be
observed for all other work.
■
Work on electrical components is only permitted while the power supply
is switched off.
■
If the magnet has a connector, only unplug this once the demagnetising
cycles has been completed and the red signal light is permanently on.
Risk from electric arc.
DANGER!
Risk of crushing!
There is risk of crushing when placing ferromagnetic parts on the active
magnet.
■
Always position workpieces while the chuck is not magnetised.
■
The use of non-magnetic tools can exclude the risk of crushing or similar
injuries.
CAUTION!
Damage!
The influence or destructive effect of magnetic chucks on electronic medical
devices, computers, watches and data carriers must be noted.
■
Keep electronic medical devices, computers, watches and data carriers
away from the exposure zone of the magnetic field.
Workstation
NOTE!
The operator’s workstation is at the machine operating area. Ensure suffi-
cient stability and fastening.
To meet the safety requirements for machinery, start-up of the machine in
setup mode has to be prevented by means of appropriate safety measures
(enable relay, see operating instructions for the control unit).
The switched-on position must be indicated with a signal lamp for electromagnetic workholding fixtures and