INSTALLATION
INSTALLATION
Installation of this water heater must be performed by an Authorised Person and
in accordance with both Local Authority Regulations and AS/NZS 3500.4 “National
Plumbing and Drainage Code and AS/NZS 3000. Wiring Rules.
LOCATION
Install as close as practicable to the kitchen or most frequently used hot water
outlet in an accessible position, and with adequate access to thermostat and
element at front of heater. Do not completely enclose unit it is essential that it
be readily removable for servicing.
CLEARANCES
Allow adequate room to work with tools. A minimum of 25mm clearance all
around the water heater including the top is required. An additional 30mm is
required for relief valve removal, 80mm for access cover removal and 400mm for
element removal. You should be able to read the information on the rating plate.
Adequate provision must be made to dispose of any escape of water from
heater or adjacent plumbing which might result in damage to property.
The water heater must be connected in such a way that the electrical junction
box is accessible to a service agent allowing the removal of the heating element
and for complete removal of the unit when necessary.
CONFINED SPACES
If the thermostat fails the unit may produce excessive steam.
It is strongly recommended that heater should be installed in well ventilated
spaces to avoid condensation build up.
If installed in confined areas, make provision for Service Access.
Vent safely to open air and carry overflow to drain.
FIG. 4