It is recommended to have the last octet of the LAN
and Backplane IP match for ease of management
1 Backplane IP for each node
It is recommended to have the last octet of the LAN
and Backplane IP match for ease of management
Network Subnet Mask
Network Gateway
All network cables and switching (including switch
configuration) should already be in place for the HC3 system
installation
A machine local to the HC3 system network for HC3 web
interface access after configuration (VPNs, port forwarding,
etc have been seen to block HC3 web interface access)
All HC3 nodes should be powered on for the HC3 system
installation
The command line login information (this will be provided by
the assigned installation specialist on installation day)
Configure the Node IPs
Log into the node using the given username and password.
Scale Computing uses a top-down system configuration with
the top node being the “first” node of the system and the
bottom node being the “last.”This “first node”
classification has no bearing on system operations
outside of the installation configuration.
If the login prompt is not shown try pressing ctrl+c to
wake the node.