10
©2011 Scaletron Industries Ltd., Plumsteadville, PA Scaletron, Scaletron Sets the Standard In Corrosion Resistance, Model 1020-1, 1020-2, Model 1099, Model 2305, Model
2306, Model 2307, Model 2308, Model 2310, Model 2330, Model 2350, Model 2352, Model 2353, Model 3001, Model 3002, Model 3003, Model 3004, Model 3005, Model 3006,
Model 3050-1, Model 3050-2, Model 4000SS, Model 4010, Model 4020, Model 4021, Model 4030, Model 4040, Model 4040IBC, Model 4041, Model 4042, and Model 4042WB
are trademarks of Scaletron Industries Ltd. Total Electronic System is a service mark of Scaletron Industries Ltd.
PRINTED IN THE U.S.A. MAY 2011.
complete. Press ESC one time to see the Net Weight screen, which will
now reflect the Net weight of the cylinders/tanks you have reloaded.
If you only have one base per channel, you will only have to lift the
cylinder/tank for that channel. Follow the same directions as written
above, or see example below.
(Example: Two Ton bases are connected to channel one. You are
loading on a new Ton cylinder with 1200 lbs tare weight (stamped on
cylinder), and you have 1100 lbs. tare stamped on the second Ton
cylinder. You replace the empty tank with a full one, and load on the
partially full tank, and proceed through the “LOAD TANK (TARE) menu by
pressing ENTER. When the scale prompts to remove empties, you have
cleared off all bases. Then you are prompted to load new cylinders. Both
cylinders are re-loaded, and you press enter. The next screen asks you to
enter the net weight. ADD the TARE weights of both cylinders you will
have re-loaded, and type that number in using the keypad. Your
combined tare weight is: 2300. You type 2-3-0-0- and press ENTER. The
screen will ask: “Are you sure?” and you will press ENTER to say Yes.
The screen will return to the head of the sub menu. At this time you know
that you have completed this function. Press the ESC key to return to the
main, “Net Weight” screen. Begin using the contents.)
Fill Tank:
When operating in Fill Tank Mode, there are a few things done for the first
use of the tank that are not repeated. It is imperative that these things be
done in the correct order to assure proper readings of the weight.
For use the FIRST time: User should place the scale into its permanent
position, level the scale if needed, and connect all wires accordingly.
Once scale base is properly installed and the empty tank is loaded, the
scale should be zeroed. This is accomplished by the following: From the
NET WEIGHT (main screen), press Display Select key twice. The LCD
will read: “ZERO A SCALE”. Press ENTER. The LCD will read: “ENTER
SCALE #1 ba”. If there is more than one channel activated, you must
zero each channel by going through the menu completely for each
channel. Choose the “Scale” or channel, by pressing ENTER. (AT THIS
TIME, BASE(S) LOADED WITH A COMPLETELY EMPTY TANK.) The
LCD will ask “ARE YOU SURE?” and you will press ENTER to say Yes.
Do this for each active channel. When each channel has been zeroed,
return to the Net Weight Screen by pressing the ESC key. This should
display a “0” for each channel activated. DO NOT ZERO THESE BASES
AGAIN WHILE A CYLINDER/TANK IS IN USE! You must now proceed to