EasyManuals Logo

Scaletron 2350 User Manual

Default Icon
7 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
4
© 2004. Scaletron Industries Ltd. Plumsteadville, PA Scaletron. Scaletron Sets The Standard In Corrosion Resistance. Model 1099, Model 2310,
Model 2330, Model 2350, Model 2352, Model 2353, Model 3001, Model 3002, Model 3003, Model 3004, Model 3005, Model 3006, Model 4010, Model
4020, Model 4021, Model 4030, Model 4040, Model 4041, Model 5305, and Pro-Gram Guide are trademarks of Scaletron Industries Ltd. Total
Electronic System is a service mark of Scaletron Industries Ltd. All Rights Reserved. PRINTED IN U.S.A. Oct 2004.
7. To complete calibration of 4-20mA output, adjust R-19 for proper 20 mA adjustment
reading. Factory setting is for 20 mA at 150.0 lb (68 kg.) unless specified otherwise.
8. Calibration is complete if specified accuracy is obtained. Repeat for second half of scale.
VI. Troubleshooting:
1. If Display reads “-1”:
A. Gross under load, turn tare knob clockwise. Numbers should reappear and can be
adjusted to tare weight or zero as required.
B. Check load cell connections at indicator and connect wires per chart on page 2
2. If Display reads “1”:
A. Gross overload, if starting point was zero, the cylinder weight is more than 199.9 lbs.,
or kg.
B. If starting point was -150 lbs. (68 kg.) then the cylinder weight is more than 349.9
lbs. (158 kg.) Remove weight and recheck tare setting.
C. Check load cell connections according to page 2, Step 4
3. If No Display:
A. Check power to weigh meter.
B. Check green light on power supply board. It should be lit. If not lit, it is shorted out.
4. Other problems: (PLEASE HAVE SERIAL NUMBER OF SCALE WHEN CALLING)
A. Consult factory:
USA & Canada Toll-Free: (800) 257-5911
Tel: (+1) 215-766-2670 Fax: (+1) 215-766-2672
Notice: Do not return any equipment without first contacting the factory. A return
authorization number will be issued and it must be marked on all materials returned to the
factory, accompanying a letter that explains the problem specifically. A Serial Number will
also be required. It is located inside the indicator box.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Scaletron 2350 and is the answer not in the manual?

Scaletron 2350 Specifications

General IconGeneral
BrandScaletron
Model2350
CategoryScales
LanguageEnglish