Combustible Wall Clearance for top vent installation:
If the stove is to be placed at side and back walls of combustible materials the following clearances
must be kept
Stove model A B C
All models
365 mm
14 inch
150 mm
6 inch
150 mm
6 inch
Combustible Wall Clearance for rear vent installation:
If the stove is to be placed at side and back walls of combustible materials the following clearances
must be kept:
Refer to the manufacturer’s instructions concerning installation of listed connector pipe, wall thimble
and chimney
You have to use a double wall connector pipe
Refer to the manufacturer’s instructions concerning installation of listed connector pipe, wall thimble
and chimney
Stove model A B D
All models 365 mm
14 inch
150 mm
6 inch
535 mm
21"