Fault Possible cause Remedy
Living area battery is not
No mains voltage Switch on the automatic
charged during 230V ope-
circuit breaker in the vehi-
-
constantly below 13.3 V)
-
tage
Too many consumers are
switched on
Switch off any consumers
not required
Defective electroblock Contact customer service
Living area battery is over-
charged during 230V ope-
ration (battery voltage
constantly above 14.5 V)
Defective electroblock Contact customer service
Starter battery is not char-
No mains voltage Switch on the automatic
ged during 230V opera-
-
circuit breaker in the vehi-
-
-
stantly below 13.0 V)
-
tage
Too many consumers are
switched on
Switch off any consumers
not required
Defective electroblock Contact customer service
Living area battery is not
Defective alternator Check the alternator
charged during mobile
No voltage on D+ input Check the fuse and wiring
below 13.0 V)
D+ switch on the electro-
block is not set correctly.
Set the switch according
to the D+ signal from the
vehicle (12V or active
ground) -- dealer
Defective electroblock Contact customer service
The living area battery is
overcharged during mo-
bile operation (battery vol-
tage constantly above
14.3 V)
Defective alternator Check the alternator
The refrigerator does not
work during mobile opera-
tion
No power supply to the re-
frigerator
Check the fuse (20A of the
supply; possibly 2A of the
D+ signal or Polyswitch)
and wiring
Defective electroblock Contact customer service
Defective refrigerator Check the refrigerator
Solar charging does not Solar charge regulator not Plug in solar charge regu-
work
plugged in
lator
Defective fuse or wiring Check fuse and wiring
Solar charge regulator de-
fective
Check solar charge regu-
lator