Instruction Manual for Electroblock EBL 271
9
Date: 14.02.2011
811.523 BA / EN
4.1 Battery functions
6-cell lead acid or lead gel batteries, 55 Ah and above
Simultaneous charging of the starter battery and the living area battery via
the alternator , parallel connection of the batteries via a cut-off relay
The switching option provided by the battery selector switch ensures opti-
mum charging of the two battery types (lead gel and lead acid).
With LT .... control and switch panel : approx. 4 mA
(depending on the control and switch panel used) under the following condi-
tions:
F
No mains connection
F
Living area battery voltage 12.6V
F
12V main switch ”OFF
Living area battery
Characteristic charging curve IUoU
End of charge voltage 14.3V
Charging current 18A
Voltage for float charge 13.8V with automatic switch function
Starter battery
Charging current float charge max. 2A
Suitable batteries
Battery charging
whilst moving
Battery selector switch
Standby current from
living area battery
(without consumer
currents)
Battery charging via
mains connector