Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: Brush Assemblies, Blade Roller
* Not necessarily included in the scope of delivery!
14. Troubleshooting guide
Fault Possible causes Rectication
Motor does not start • No electricity in plug
• Cable defective
• Switch, switch/plug block defective
• Connections to motor or capacitor
disconnected
• Blade roller blocked
• Check line and fuse
• Have machine checked by a customer service
center
• Have machine checked by a customer service
center
• Have machine checked by a customer service
center
• If necessary adjust working depth. Clean housing
so that the roller can run freely
Engine performance
drops
• Soil is too rm
• Carbonbrushes worn out
• Roller badly worn
• Change working depth
• Check by a customer service center
• Replace roller
The Electric Tiller is
di󰀩cult to check.
• roller worn
• Wrong working depth
• Replace roller
• Correct working depth
Motor is running, roller
is not rotating
• Gearing defective • By customer service workshop