Do you have a question about the Schischek ExMax Series and is the answer not in the manual?
Details the ExMax actuators of size M, covering their features and applications in hazardous environments.
Lists key features such as universal supply, multiple running times, overload protection, and compact design.
Shows typical applications for ExMax actuators in various industrial settings like HVAC and chemical plants.
Details ATEX certifications, gas/dust approvals, EMC, low voltage, and IP protection ratings.
Covers product identification, EMC compliance, low voltage directive, and potential compensation.
Provides wiring diagrams for ExMax actuators without spring return and with integral auxiliary switches.
Details the wiring diagram for ExMax actuators equipped with a spring return function.
Explains how to select parameters using the 10-position switch and perform self-adjustment.
Provides information on error signals and their meaning for troubleshooting.
Covers essential steps for installation, commissioning, and maintenance, including safety precautions.
Details shaft connection, selection of running time, and operation of the integral heater.
Addresses 3-pos control, spring return, low temperature, excess temperature, and synchronous mode.
Describes ExSwitch and ExBox accessories for mounting on air dampers.
Provides guidance on designing the power supply for ExMax actuators.
Details how to calculate the necessary supply line cross-section to prevent voltage drops.
Shows wiring diagrams for on-off/3-pos actuators without and with spring return.
Presents wiring alternatives for BF actuators using Ex-i circuits and limiters.
Lists the electrical parameters for intrinsic safe (Ex-i) circuits.
Details wiring for modulating actuators with/without spring return and feedback.
Covers temperature rise, 3-pos operation, and low ambient temperature usage.
Discusses mechanical protection and automatic alignment procedures.
Addresses scenarios where the actuator does not work and the LED status is abnormal.
Details faults related to 3-pos mode, diagonal mounting, and reduced angle of rotation.
Covers errors due to irregular LED flashing, insufficient supply voltage, or long cables.
Provides physical dimensions, drill templates, and details on the control interface.
Offers specifications and advice for installing actuators in outdoor environments.
Details mounting procedures for actuators on air dampers using square shaft connections.
Explains mounting to ball valves and butterfly valves, requiring special brackets.
Covers assembly and mounting instructions specifically for fire dampers.
Describes mounting terminal boxes (ExBox, RedBox, InBox) using MKK-M brackets.
Details the mounting process for ExSwitch, RedSwitch, and InSwitch accessories.