11.1 TABLE 1 CAPACITY SELECTION CHART (MAX SCFM @ APPROACH)
INLET TEMP F
150
200
250
300
350
Above specifications are based on 80 to 125 psig operating pressures. Maximum pressure drop is less than 3 psi.
11.2 TABLE 2 AFTERCOOLER ELECTRIC MOTOR, AIR MOTOR & FAN DATA
ELECTRIC MOTOR
AIR MOTOR
All motors shown are TEFC. Published electrical ratings are approximate and may vary because of motor
brand. Actual ratings are on motor nameplate. Fan motors must not be cycled. Outdoor applications must
be protected from direct weather. If ductwork or additional static resistance is added to the cooler air
stream, an auxiliary air mover may be required.
1. Air inlet to the air motor must be regulated to this pressure.
2. CFM (Free Air) consumption of the air motor. Lubrication = One drop of oil per minute for every
50 cfm of air passing through the air motor.
3. Drip rate is the recommended drops of oil that enters the air motor per minute based on the CFM.
Two types of lubricators have been used in Schmidt® AirPrep Systems. Current production units
are equipped with “oil-fog” lubricators (Style MP). Systems manufactured prior to September 2016
are equipped with “micro-fog” lubricators (Style L74M). Note: Micro-fog lubricator drip rates are
significantly higher because only a fraction of the drip total enters the air stream.
APPROACH TEMP F
5
10
15
20
5
10
15
20
5
10
15
20
5
10
15
20
5
10
15
20
AIR DRYER
SYSTEM
MODEL
NUMBER
ADS 250
191
250
275
300
117
160
200
250
96
120
165
200
87
117
151
191
81
104
129
159
ADS 400
210
384
520
605
175
375
430
500
160
300
400
464
135
250
340
396
125
235
305
355
ADS 750
355
650
890
1025
308
560
760
880
290
545
725
840
245
450
605
701
225
410
540
625
ADS 950
480
871
1178
1360
415
754
1020
1180
390
712
950
1100
320
588
785
910
280
520
690
780
ADS 1200
600
1090
1475
1710
520
950
1290
1460
490
900
1200
1380
405
735
980
1130
355
650
865
990
ADS 1600
790
1440
1950
2260
710
1290
1720
1950
660
1200
1600
1860
530
965
1290
1480
460
840
1135
1300
ADS 2000
980
1790
2420
2800
870
1580
2140
2460
820
1490
2000
2300
660
1210
1595
1840
572
1040
1400
1610
ADS 2500
1220
2200
3000
3470
1090
1980
2680
3100
1035
1880
2500
2870
784
1426
1980
2270
705
1290
1725
1980
MODEL
NO.
FAN
CFM
HP VOLTAGE PHASE
FULL LOAD
AMPS (230V)
HZ RPM
NEMA
FRAME
THERMAL
OVERLOAD
INLET
NPT
PSI
(1)
CFM
(2)
DRIP RATE (3)
Micro-fog Oil-fog
ACS 250 1325 0.5
115/230
208-230/460
1
3
3.4
1.2
60
50/60
3450 IEC71
NO
1/4 35 30 15 1
ACS 400
2200
1825/2200
1.0
115/208-230
208-230/460
1
3
6.0
3.6/3.2
60
50/60
3450
2850/3450
56C 1/4
60 50 19 1
ACS 750
3600
3025/3600
1.5
115/208-230
208-230/460
1
3
8.5
4.8/4.2
60
50/60
3450
2850/3450
85 45 19 1
ACS 950 4700 1.5
115/208-230
208-230/460
1
3
8.6
4.6
60 1740
145TC
1/2
60 55 22 1
ACS 1200 7000
5.0 230 1 23.0 184TC
70 100 30 2
3.0 208-230/460 3 8.8 182TC
ACS 1600 9700 5.0 208-230/460
3
13.4 184TC 1 100 180 54 4
ACS 2000 11000
7.5 230/460 19.6 213TC 1-1/4 90 230 69 5
ACS 2500 14000
11.0 AirPrep System Technical Data and Troubleshooting