Commissioning instructions – Schüco DCS Touch Display 21
Dok-Nr.10000432116_01
INFORMATION
SELV electrical circuit
The relay output must only be used for SELV electrical circuits. A SELV electrical circuit in accordance
with IEC/EN 60950-1 must be securely isolated (e.g. by means of double insulation) from a
dangerous electrical circuit (e.g. 230 V or 110 V mains supply circuit) and must not exceed the
voltage value of 60 V DC or 42.4 V ACpeak (30 V ACeff).
IP secure connector circuit breakers
All inputs and outputs of the IP secure connector are protected against voltages up to 60 V DC and
42 V AC. The „DC-OUT 3“ output also has circuit breakers to protect against external supply, short
circuiting and reverse polarity.
You can nd examples of connecting LED spotlights and/or motion detectors in Chapter 10,
„Connection examples“, in the installation instructions. .