Schweitzer Engineering Laboratories, Inc. SEL-2245-4 Data Sheet
The SEL-2245-4 provides ac metering inputs for the SEL Axion
®
. Within an Axion node, install as many as sixteen
SEL-2245-4 modules per system in any combination you want.
Front Panel
Figure 1 SEL-2245-4 AC Metering Module
Mechanical Installation
Each SEL-2242 chassis/backplane has four or ten slots,
labeled AJ. Slots BJ support the SEL-2245-4 modules.
Figure 2 Notch for Module Alignment
To install an SEL-2245-4 module, tip the top of the
module away from the chassis, align the notch on the
bottom of the module (shown in Figure 2) with the slot
you want on the chassis, and place the module on the
bottom lip of the chassis as Figure 3 illustrates. The
module is aligned properly when it rests entirely on the
lip of the chassis.
i6316a
SEL-2245-4 AC Metering Module
Question and Answer IconNeed help?

Do you have a question about the Schweitzer Engineering Laboratories SEL-2245-4 and is the answer not in the manual?

Schweitzer Engineering Laboratories SEL-2245-4 Specifications

General IconGeneral
ModelSEL-2245-4
CategoryControl Unit
Operating Temperature-40°C to +85°C
Number of Ports4
Communication PortsEthernet
ProtocolsDNP3, Modbus
MountingDIN Rail
Power Supply24–60 VDC or 85–264 VAC
Port TypeEthernet
Weight2.2 lb (1 kg)

Summary

Front Panel and Mechanical Installation

Front Panel Overview

Diagram of the SEL-2245-4 AC Metering Module front panel, showing terminals and indicators.

Module Installation Procedure

Steps for installing the SEL-2245-4 module into the chassis, including alignment.

Module Connections and Indicators

Input Connections

Description of CT/PT analog inputs and terminal conventions for the module.

LED Indicators

Explanation of the ENABLED and ALARM LEDs and their relation to network operation.

Specifications

General Specifications

Compliance, operating environment, and general operating parameters for the module.

AC Metering Inputs

Details on frequency, accuracy, phase rotation, and input configuration for AC metering.

Current Inputs

Specifications for phase and neutral current inputs, including range, accuracy, and burden.

Voltage Inputs

Specifications for voltage inputs, including nominal voltage, measurement range, and maximum values.

Power and Power Factor

Accuracy specifications for per-phase and three-phase power and power factor measurements.

Synchrophasor Measurements

Conformance, accuracy, and processing rate for synchrophasor measurements.

Triggered Waveform Recording

Details on sampling rates and record duration for waveform recording.

Environmental and Electrical Tests

Environmental Test Types

Details on enclosure protection, vibration, shock, seismic, and temperature/humidity tests.

Dielectric and Impulse Tests

Specifications for dielectric strength and impulse tests, including HiPot.

RFI and Interference Tests

Immunity tests for electrostatic discharge, radiated RF, digital radio, and conducted RF.

Immunity and Emissions Standards

Details on surge immunity, transient immunity, magnetic field immunity, and emissions.