Service Diagnosis
•Makes ice, but ice is cloudy or not completely
formed
– Spray jets restricted, clean machine
– Lack of rinse water due to hot room temperature
• Adjust harvest time longer to drain more water
•Makes ice but they are blocks or shells
– Ice bridge wrong size
– Evaporator thermistor out of calibration
– Evaporator thermistor failure
– Poor contact of thermistor probe to suction line