Service Diagnosis
Makes ice, but ice is cloudy or not completely
formed
Spray jets restricted, clean machine
Lack of rinse water due to hot room temperature
Adjust harvest time longer to drain more water
Makes ice but they are blocks or shells
Ice bridge wrong size
Evaporator thermistor out of calibration
Evaporator thermistor failure
Poor contact of thermistor probe to suction line