Service Diagnosis
•Makes ice but does not fill the bin, cycle times
are correct
– Bin thermostat opens and shuts machine off before
bin is full, check room temperature
• Adjust thermostat if room is below 60 degrees F.
• Machine located over 2000 ft. above sea level, correct by
making thermostat altitude adjustment.
• Thermostat out of calibration, replace
– Bin drain restricted
• Drain tubing vented? Correct slope and size?
• Flush or blow out bin drain