Component Operation Indicator Lights
Code Description
.... ......Freeze Cycle
flashes....Freeze Cycle is Pending
.... ......Harvest Cycle
flashes....Manual Harvest
.... ......BinisFull
.... ......Clean Cycle
.... ......Board Locked
.... ......TestMode
.... ......Off
.... ......Self Test Failed
flashes....MaxFreeze - Retrying
..... ......MaxFreeze Time Shut Down
flashes....MaxHarvest - Retrying
.... ......MaxHarvest Time Shut Down
.... ......Slow Water Fill
.... ......High Discharge Temp
.... ......Sump Temp Sensor Failure
.... ......Discharge Temp Sensor Failure
flashes . . . Short Freeze - Retrying
Short Freeze - Thin ice
- Unit Remotely
Locked Out - Contact Leasing Company
F
F
H
H
b
C
L
d
O
E
1
1
2
2
3
4
5
7
8
8............
All 4 Upper Lights Flashing
Control Operation - See Manual
Water Light On
De-Scale Light On
Flush Setting
Test Mode
Recall Diagnostic Codes
Reset from Code 1, 2, 4 or 8
- Restore water supply to
machine.
- Clean and sanitize
machine.
- To Change: Depress Off
for 3 seconds. Press On to select purge
(1-5) setting or A for Automatic.
- Depress Off for 3 seconds,
then depress Clean for 3 seconds.
- Depress Off
for 3 seconds. Press Harvest repeatedly
to go from most recent to oldest of 10.
- Depress
Off then Depress On.