Page 3
Page 3
Important operating requirements:
Air temperature
Water temperature
Water pressure
Electr. voltage variations
from voltage rating
specified
on nameplate
MIN.
10°C
5°C
1 bar
-10%
°C
°F
SPECIFICATIONS
CUBER MODEL EC 46
NOTE
. With the unit in "built-in" conditions, the ice production is gradually reduced in respect to the
levels shown in the graf, up to a maximum of 10% at room temperatures higher than 32
°
C.
The daily ice-making capacity is directly related to the condenser air inlet temperature, water
temperature conditions of the condenser air filter and age of the machine.
To keep your SCOTSMAN CUBER at peak performance levels, periodic maintenance checks must
be carried out as indicated on Maintenance and Cleaning section of this manual.
MAX.
40°C
35°C
5 bar
+10%
ice making capacity
25
24
23
22
21
20
19
18
17
16
Kg.
32 27 21 15 10
AIR COOLED MODELS
WATER TEMPERATURE
AMBIENT TEMPERATURE
ICE PRODUCED PER 24 HRS.
10
21
32
38
WATER COOLED MODELS
°C
o
°C
o
25
24
23
22
21
20
19
18
17
16
Kg.
32 27 21 15 10
10
21
32
38
°C
o
°C
o
WATER TEMPERATURE
AMBIENT TEMPERATURE
ICE PRODUCED PER 24 HRS.