This ice cube is clear, solid
but it is very thin with a very
big depression on its bottom
rim due to a very short
freezing cycle.
In this situation may be the PC
Board by-passed the first two
portions of the freezing cycle -
Time T
1
+ T
2
- due to a
inoperative evaporator sensor.
NEW MXG SERIES
SERVICE ANALYSIS