3. Technical information
o The complete blower unit consists of a blower, a breathing hose, a belt, a battery, a recharger and a
transformer.
Two thread lters must be attached to the blower device. The connection thread of the lters and the
breathing hose of the blower device conforms to the standard EN 148-1.
o Rechargeable Ni-Cd battery 4,8 V/5 Ah.
o Red signal lamp indicates when the air ow rate falls below the required minimum.
o At a very intensive working pace, the air ow rate 120 l/min will provide a better protection than the
ow rate 65 l/min. At a lighter working pace, the ow rate of 120 litres may feel uncomfortable on the
face. Also, recharging will be needed more often and the motor lifetime will be shortened.
Automatic regulation of the
air ow rate
Operating time on fully
charged battery
Weight of the blower
device without lters
Auto ow 120
Auto ow 65/120
minimum 120 l/min
minimum 65 l/min
minimum 5 hours
minimum 5 hours
1,4 kg
1,4 kg
Selection of blower-assisted breathing protector equipped with lter
Type of protective device Multiples of threshold
concentration **)
Remarks, limitations
APF (Assigned protection factor)
BS 4275 (GB)
BGR 190 - ZH1/701 (DE)
Power-assisted half mask
with particle lter TM2P
Power-assisted full face
mask with particle lter TM3P
20
40
100
500
Power-assisted face shield or welding shield
with particle lter
TH1P
TH2P
TH3P
10
20
40
5
20
100
“Open” facepieces, such as helmets or hoods, do not
provide suf cient protection in case of breakdown or
inferior output of the blower. Therefore, devices of class
TH1 must never be used against carcinogenic, very
poisonous or radioactive gases and vapours.
Device with combined lter The speci ed multiples of threshold value for the gas or particle lters are given
separately, but in all cases the lowest value applies.
Power-assisted half mask with gas lter *)
TM2 gas lter class 1, 2 or 3
Power-assisted full face mask with gas lter
*)
TM3 gas lter class 1, 2 or 3
20
40
100
500
Power-assisted face shield or welding shield
with gas lter *)
TH1 gas lter class 1 or 2
TH2 gas lter class 1 or 2
TH3 gas lter class 1 or 2
10
20
40
5
20
100
For devices with combined lter apply the relevant
limitations of gas and particle lters.
*) Provided that the maximum permissible detrimental gas concentration for the gas lter is not exceeded. For
power-assisted ltering devices with gas lter, concentration must not exceed 0.05 vol.% in gas lter class 1 and
0.1 vol.% in gas lter class 2 and 0.5 vol.% in gas lter class 3.
**) If national guidelines exist: in all cases the lowest value applies.