4. Battery
General
o Charge the battery before use. The recharging time of an empty battery is about 14 hours. The
temperature of the battery to be recharged must be +10 °C...+ 30 °C.
o Recharging should always take place at a room temperature of about +20 °C, in a dry place
shielded from dust and direct sunlight.
o Always use the Auto ow’s own battery, recharging device and transformer (which are delivered
with the blower unit).
o The battery can also be charged partially. By one hour recharge the battery will operate from 2 to 4
hours. The operating period of the battery depends on e.g. breathing resistance (load).
Note!
o In too cold/warm an environment the the recharging device will suppress the charging current to
standby level, so the battery will not be charged.
o A new battery or a battery stored for a longer period may not function stably, which will terminate
the recharging prematurely. Monitor the signal lights during the rst few rechargings and initiate
the recharging several times if needed.
o Never recharge in a potentially explosive environment!
o Discarded batteries are hazardous waste. Make sure that they are disposed of according to waste
treatment regulations.
Recharging
Connect the transformer to the main power supply (220-240 V/ 50 Hz) and to the recharging
device Æ both signal lights on the recharger will turn on. The signal light on the left will turn off
after ca 5 seconds but the one on the right will remain on.
Connect the battery to the recharger Æ the left signal light will turn on again.
Throughout the recharging, both signal lights will remain on. The time needed depends on the
battery status.
Recharging is complete when the right signal light goes out, and the left remains burning (standby
level).
5. Start-up
See Instructions for Use of the facepiece and the lter to be used.
Always use 2 lters of the same type and class.
Insert the charged battery into the blower device, ensuring that the battery locks rmly.
Check before use
intactness of facepiece and blower device
lters are intact and properly fastened to the blower device. Shake the lter to ensure that there are
no loose components/contents. The lter shall be replaced if it has been exposed to strong press
or impact. It may be damaged.
breathing hose is tightly xed to the blower device and facepiece
adequate air ow as follows:
- Assemble all items ready for use (facepiece connected) but do not don the unit.
- Start the blower.
- The air ow is suf cient if if the blowers red signal light goes out after the device is switched
on.