5.10 Storage
Storage protected from direct sunlight, at -10...+50 °C and relative humidity (RH) under 75 %
(sealed filters RH max. 95 %). A properly stored, unused mask stays in good condition for a
long storage period.
The components should not be more than 12 years old.
Before use, the mask must undergo a function test, see Table.
After use, an opened filter must be sealed tightly if it is to be reused, but it must be replaced
within 6 months at the latest.
5.11 Disposal
Masks (without filters) are coarse waste. A very contaminated mask and used filters are special
refuse and shall be disposed of according to the filtered substances (gases or particles).
5.11 Australia and New Zealand
For complete national requirements, please refer to the standard AS/NZS1715:2009, Use &
Maintenance of Respiratory Products.
Component
Work to be done
Intervals
Before
use
After
use
Every
year
Every 6
years
Mask,
complete
Cleaning
Disinfection
Test for function and leak-tightness/Pro-Tester
Pre-use check done by the user, according to
point 4
Replace: visor, head harness, buckles, inner
mask and other parts
*)
*)
Valve discs
(6a, 6b, 6c)
Check
Replace
Check tightness of exh. valve disc/Pro-Tester
*)
Inhalation
valve
Check valve seat (part 5a)
Speech
diaphragm (9)
Check
Replace
Drinking device
Cleaning
*) when needed