MK17 revision may 2005 1 / 1
MAINTENANCE PROCEDURE FOR MK17
Question and Answer IconNeed help?

Do you have a question about the SCUBAPRO-UWATEC MK17 and is the answer not in the manual?

SCUBAPRO-UWATEC MK17 Specifications

General IconGeneral
Environmentally SealedYes
MaterialChrome-plated brass
Ports4 LP
Nitrox compatibilityYes
Maximum Working Pressure232 bar (3364 psi)
TypeFirst Stage Regulator

Summary

Disassembly

Initial Disassembly Steps

Unscrew hoses, remove plugs and o-rings, inlet protector, and rubber bumpers.

HP Port Disassembly Procedures

Use field handle tool on HP ports for INT and DIN version disassembly.

Internal Component Removal

Remove diaphragm retainer, spring, dry ambient chamber, and internal components.

Balance Chamber and Orifice Removal

Disassemble balance chamber and carefully remove the orifice.

Assembly

INT Version Assembly

Assemble filter, retainer, and o-ring for INT version yoke retainer.

DIN Version Assembly

Assemble o-ring, retainer, and wheel for DIN version.

Filter, Spring, and Tank O-ring Installation

Install conical filter, spring, and tank o-ring with specified torque.

Orifice and Balance Chamber Assembly

Insert orifice with o-ring and assemble balance chamber components.

HP-Poppet and System Integration

Insert HP-poppet into balance chamber and the whole system into the 1st stage.

Diaphragm and Dry Chamber Installation

Place diaphragm components and screw dry ambient chamber securely.

Final Reassembly and Checks

Reassemble plugs, hoses, and bumper caps after pressure testing.

Adjustment Phase

Preparation for Adjustment

Connect 1st stage to a full tank and attach a precise interstage pressure gauge.

Pressure Observation and Cycling

Observe gauge needle movement and cycle regulator to set internal parts.

Interstage Pressure Adjustment

Adjust interstage pressure to 9-10 bars using the adjustment screw.

Troubleshooting and Final Steps