ADD: No. 46, Haichuan Road, Jining High-tech Zone, Shandong Province,
272000, P. R. China

Questions and Answers

  • T
    Todd DorseyAug 14, 2025
    Why is the red detection indicator on for my SDKELI KS06 AOPD?
    • J
      joshuayoungAug 14, 2025
      If the red detection indicator is on for your SDKELI Safety Equipment, it could be due to contact adhesion for one relay. The suggested solution is to replace the two relays with the same specification ones.
  • A
    Anthony EdwardsAug 18, 2025
    How to troubleshoot if AOPD is not working and all indicators are off in SDKELI Safety Equipment?
    • P
      Paul CisnerosAug 18, 2025
      If the AOPD (Area of Operation Protective Device) on your SDKELI Safety Equipment isn't working and all indicators are off, there are several potential causes: * **No supply voltage:** Ensure the correct power supply is connected. * **Controller fault:** Further diagnostics may be needed.
  • S
    Stephen BatesAug 21, 2025
    What to do if power indicator and unusual station indicator are on, but normal operation indicator is off in SDKELI Safety Equipment?
    • D
      davidjosephAug 21, 2025
      If the power indicator and unusual station indicator are on, but the normal operation indicator is off for your SDKELI Safety Equipment, it could be due to: * The green status indicator of the receiver being off. * Wiring or transmission cable fault. Check and repair the transmission cable, replacing it if broken.
  • A
    Ashley WileyAug 25, 2025
    What to do if the conversion indicator is normal, but press is not able to work with SDKELI KS06 AOPD?
    • T
      Tonya CombsAug 26, 2025
      If the conversion indicator is normal, but the press isn't working with your SDKELI Safety Equipment, it may be due to: 1. A cut or incorrect connection between the OSSD output signal cable terminals and the electric part of the machine: Check and repair the electric circuit of the machine connected with OSSD, and ensure the connection is correct. 2. An open circuit in the output signal cable: Repair or replace the output signal cable. 3. An electric fault of the machine: Check and repair the electric circuit of the machine.
  • R
    ryanhunterAug 27, 2025
    What to do if turning the function switch to the non-protection side makes the press not able to work on SDKELI KS06 AOPD Safety Equipment?
    • T
      tanyamcdanielAug 28, 2025
      If turning the function switch to the non-protection side prevents the press from working with your SDKELI Safety Equipment, possible causes include: * A break in the electric circuit of the machine connected with OSSD: Check and repair the electric circuit of the machine connected with OSSD, ensuring the connection is correct. * An open circuit in the output signal cable: Repair or replace the output signal cable. * Disconnection in the loop of electric stroke for the machine: Check and repair the electric circuit of the machine.
  • S
    stephen31Aug 31, 2025
    Why is press not able to work when the conversion of indicator is normal for SDKELI KS06 AOPD Safety Equipment?
    • J
      James DudleyAug 31, 2025
      If the conversion of indicator is normal, but the press is not able to work with your SDKELI Safety Equipment, it could be due to: * The fuse F1 fusing: Replace the power fuse with a new one of the same specification, 5×20/5A. * The circuit between OSSD breaks: Check and repair the circuit and wiring of OSSD. * The contact point of relay is ageing or broken: Replace the relay with the same specification one. * Electric fault of machine: Check and repair the circuit and wiring of OSSD; if the wiring is correct, check and repair the electric circuit of the machine.
  • C
    Catherine ShawSep 4, 2025
    Why is AOPD working intermittently and the conversion of indicator is abnormal in SDKELI KS06 AOPD?
    • M
      Melissa FlynnSep 4, 2025
      If the AOPD (Area of Operation Protective Device) on your SDKELI Safety Equipment works intermittently and the indicator conversion is abnormal, it may be due to: * Low supply voltage or bad contact in the circuit: Couple in the correct power supply or correct the bad contact. * Bad beam focusing: Readjust the position of the emitter and receiver to ensure proper beam focusing.
  • Z
    zwilsonSep 7, 2025
    What causes the AOPD to not work and all indicators to be off on SDKELI KS06 AOPD Safety Equipment?
    • J
      Jeremy CarpenterSep 7, 2025
      If the AOPD does not work and all the indicators are off on your SDKELI Safety Equipment, this could be caused by: * No supply voltage: Couple in the correct power supply. * The power fuse blowing out: Replace the power fuse with a new one of the same specification, 5×20/1A. * Power cable fault or bad contact for socket connector: Check and repair the power cable and socket connector. * Power switch broken or bad contact for connector, or relevant circuits broken: Replace the key switch, or check and repair connector and relevant circuit. * The switch mode power is broken: Check the connection of circuit and socket connector, replace the switch mode power if the wiring is correct.
  • J
    jonathan51Sep 10, 2025
    What to do if shading the light curtain doesn't stop the press on SDKELI KS06 AOPD Safety Equipment?
    • J
      Jermaine SmithSep 12, 2025
      If, when you shade the light curtain, the press does not stop on your SDKELI Safety Equipment, the issue could stem from: * A short circuit in the electric circuit of the machine connected with OSSD: Check and repair the electric circuit of the machine connected with OSSD. * A short circuit in the output signal cable: Replace the cable and its connector. * A short circuit in the circuit of the cam switch for muting function: Check and repair the circuit of the cam switch for muting function. * A fault in the braking of the machine: Check the machine.

Summary

Section1 Product description

1.1 System components

Overview of the protective system's constituent parts including controller, light curtain, and cables.

1.1.1 Light curtain

Describes the emitter and receiver functions of the light curtain system.

1.1.2 Controller

Details the controller's role in power supply, signal processing, and output control.

1.1.3 Transmission cable

Lists specifications and diagrams for transmission cables connecting system components.

1.1.4 Power cable

Explains the power cable connections for the AOPD and controller.

1.2 Specifications

Provides a breakdown of the entire machine specification for AOPD and safety light curtains.

1.3 Technical parameters

Lists detailed technical specifications for controllers and safety light curtains.

1.3.1 KS06 AOPD;KS06 G safety light curtain Parameter table

Presents a parameter table for KS06/KS06G safety light curtains by beam spacing.

1.3.2 KS06 cascaded AOPD;KS06 G cascaded safety light curtain Parameter table

Provides parameter tables for cascaded AOPD/KS06G safety light curtains.

1.4 Dimensions of major parts

Illustrates the physical dimensions of key components like controllers, emitters, and receivers.

Section2 Installation and wiring

2.1 Installation requirements

Outlines essential requirements and warnings for the safe installation of the system.

2.1.1 Detection zone and installation method

Details how to establish the detection zone and proper installation techniques.

2.1.2 Safety distance

Explains how to calculate and ensure the safety distance for proper operation.

2.1.3 Distance from reflective surfaces

Specifies the required distance from reflective surfaces to avoid detection interference.

2.1.4 Mutual interference prevention

Advises on preventing interference between multiple safety light curtain systems.

2.2 Installation

Provides instructions for mounting the controllers and system components.

2.2.1 Mutual interference prevention

Details controller installation, focusing on preventing mutual interference.

2.2.2 Mutual interference prevention

Discusses emitter/receiver installation and alignment to prevent interference.

2.3 Wiring

Covers the electrical wiring procedures for the system components.

2.3.1 Matters needing attention

Highlights critical safety warnings and considerations before performing wiring.

2.3.2 Wiring about CPSII controller

Provides specific wiring diagrams and instructions for the CPSII controller.

2.3.3 Wiring about CQ2 controller

Offers wiring details and diagrams for the CQ2 controller.

2.3.4 Wiring about KS06 G Safety Light Curtain

Details the wiring for KS06G safety light curtains, including PNP and NPN outputs.

2.3.5 Wiring about KS06 G Cascaded Safety Light Curtain

Explains the wiring for cascaded KS06G safety light curtains.

Section3 Check and debugging

3.1 Installation condition check

Lists checks to verify proper installation and safety function of the system.

3.2 Wiring check before power is turned on

Outlines crucial checks to perform on wiring before applying power.

3.3 Operation check while the machine is stopped

Describes how to test the light curtain's operation when the machine is not running.

3.4 Checking that hazardous parts stop while the machine operates

Details how to verify that hazardous parts stop correctly when the light curtain is activated.

3.5 Debugging

Guides on troubleshooting and fine-tuning the system's performance after installation.

Section4 Maintenance

4.1 Inspection at startup and when changing operators

Specifies inspections required during initial setup and operator changes.

4.2 Inspection for the guarded machine

Outlines checks for the machine being protected by the light curtain.

4.3 Items to inspect every 6 months or when machine settings are changed

Lists periodic maintenance checks and items to inspect after setting changes.

Section5 Troubleshooting

Disassemble of AOPD and machine

Lists common faults, their causes, and solutions for the AOPD and machine.

Troubleshooting of controller

Provides a guide to diagnose and resolve issues related to the system controller.

Troubleshooting of emitter;receiver

Offers solutions for common problems encountered with the emitter and receiver units.

I. Legislation and standards

II. User instructions

III. Precautions on safety

IV. Precautions for safe use

V. Meaning of symbols

SDKELI KS06 AOPD Series Specifications

General IconGeneral
Detection MethodInfrared
Output TypeNPN/PNP
Protection LevelIP65
Housing MaterialAluminum alloy
Power SupplyDC 12V - 24V
Operating VoltageDC12~24V
Operating Temperature-10°C to +55°C
WeightVaries by model
Storage Temperature-20°C to +70°C